S-8240A Series
 Battery Protection IC Connection Example
EB+
R1
VDD
Battery C1
S-8240A Series
VSS
DO
CO
VM
R2
FET1
FET2
EB−
Figure 16
Table 13 Constants for External Components
Symbol Part
Purpose
Min.
Typ.
Max.
Remark
FET1
N-channel
MOS FET
Discharge control
−
−
−
Threshold voltage ≤ Overdischarge
detection voltage*1
FET2
N-channel
MOS FET
Charge control
−
−
−
Threshold voltage ≤ Overdischarge
detection voltage*1
R1
Resistor
ESD protection,
For power fluctuation
270 Ω 330 Ω 1 kΩ
−
C1
Capacitor For power fluctuation
0.068 μF 0.1 μF
1.0 μF
Caution should be exercised when
setting VDIOV ≤ 20 mV, VCIOV ≥ −20 mV.*2
ESD protection,
Caution should be exercised when
R2
Resistor Protection for reverse
300 Ω 470 Ω 4 kΩ an FET with a large gate capacitance
connection of a charger
is used.*3
*1. If an FET with a threshold voltage equal to or higher than the overdischarge detection voltage is used, discharging may
be stopped before overdischarge is detected.
*2. When setting VDIOV ≤ 20 mV, VCIOV ≥ −20 mV for power fluctuation protection, the condition of R1 × C1 ≥ 47 μF •
Ω should be met.
*3. If an FET with a gate capacitance equal to or more than 5 nF is used, charge overcurrent detection voltage may
become lower when R2 resistance is large. R2 resistance should be set to a smaller value when an FET with a gate
capacitance equal to or more than 5 nF is used.
Caution 1. The above constants may be changed without notice.
2. It has not been confirmed whether the operation is normal or not in circuits other than the above
example of connection. In addition, the example of connection shown above and the constant do not
guarantee proper operation. Perform thorough evaluation using the actual application to set the
constant.
25