BATTERY PROTECTION IC FOR 1-CELL PACK
S-8240A Series
Rev.2.1_01
3. Overdischarge status
When the battery voltage falls below VDL during discharging in the normal status and the condition continues for the
overdischarge detection delay time (tDL) or longer, the S-8240A Series turns the discharge control FET off to stop
discharging. This condition is called the overdischarge status.
Under the overdischarge status, VDD pin and VM pin are shorted by RVMD in the S-8240A Series. The VM pin voltage
is pulled up by RVMD.
RVMS is not connected in the overdischarge status.
3. 1 With power-down function
Under the overdischarge status, when voltage difference between VDD pin and VM pin is 0.8 V typ. or lower, the
power-down function works and the current consumption is reduced to the current consumption during power-
down (IPDN). By connecting a battery charger, the power-down function is released when the VM pin voltage is
0.7 V typ. or lower.
• When a battery is not connected to a charger and the VM pin voltage ≥ 0.7 V typ., the S-8240A Series
maintains the overdischarge status even when the battery voltage reaches VDU or higher.
• When a battery is connected to a charger and 0.7 V typ. > the VM pin voltage > 0 V typ., the battery voltage
reaches VDU or higher and the S-8240A Series releases the overdischarge status.
• When a battery is connected to a charger and 0 V typ. ≥ the VM pin voltage, the battery voltage reaches VDL or
higher and the S-8240A Series releases the overdischarge status.
3. 2 Without power-down function
The power-down function does not work even when voltage difference between VDD pin and VM pin is 0.8 V typ.
or lower.
• When a battery is not connected to a charger and the VM pin voltage ≥ 0.7 V typ., the battery voltage reaches
VDU or higher and the S-8240A Series releases the overdischarge status.
• When a battery is connected to a charger and 0.7 V typ. > the VM pin voltage > 0 V typ., the battery voltage
reaches VDU or higher and the S-8240A Series releases the overdischarge status.
• When a battery is connected to a charger and 0 V typ. ≥ the VM pin voltage, the battery voltage reaches VDL or
higher and the S-8240A Series releases the overdischarge status.
4. Discharge overcurrent status (discharge overcurrent, load short-circuiting)
When a battery in the normal status is in the status where the VM pin voltage is equal to or higher than VDIOV because
the discharge current is equal to or higher than the specified value and the status lasts for the discharge overcurrent
detection delay time (tDIOV) or longer, the discharge control FET is turned off and discharging is stopped. This status
is called the discharge overcurrent status.
4. 1 Release condition of discharge overcurrent status "load disconnection" and release voltage of
discharge overcurrent status "VDIOV"
Under the discharge overcurrent status, VM pin and VSS pin are shorted by RVMS in the S-8240A Series.
However, the VM pin voltage is the VDD pin voltage due to the load as long as the load is connected. When the
load is disconnected, VM pin returns to the VSS pin voltage.
When the VM pin voltage returns to VDIOV or lower, the S-8240A Series releases the discharge overcurrent
status.
RVMD is not connected in the discharge overcurrent status.
4. 2 Release condition of discharge overcurrent status "load disconnection" and release voltage of
discharge overcurrent status "VRIOV"
Under the discharge overcurrent status, VM pin and VSS pin are shorted by RVMS in the S-8240A Series.
However, the VM pin voltage is the VDD pin voltage due to the load as long as the load is connected. When the
load is disconnected, VM pin returns to the VSS pin voltage.
When the VM pin voltage returns to VRIOV or lower, the S-8240A Series releases the discharge overcurrent
status.
RVMD is not connected in the discharge overcurrent status.
4. 3 Release condition of discharge overcurrent status "charger connection"
Under the discharge overcurrent status, VM pin and VDD pin are shorted by RVMD in the S-8240A Series.
When a battery is connected to a charger and the VM pin voltage returns to VDIOV or lower, the S-8240A Series
releases the discharge overcurrent status.
RVMS is not connected in the discharge overcurrent status.