S-8239A Series
Table 7 Constants for External Components
Symbol
Min.
Typ.
Max.
Unit
RVDD
RVINI
RSENSE
RVM
RDO*3
RDOP
CVDD
300
470
1000
Ω
1
−
−
kΩ
0
−
−
mΩ
1
5.1
51
kΩ
−
5.1
−
kΩ
330
510
2000
kΩ
0.022
0.1
1
μF
*1. Refer to the data sheet of the S-8225A Series for the recommended value for external components
of the S-8225A Series.
*2. Use the products with the same model number for FET1 and FET2.
*3. Set up the optimal constant according to the FET in use.
Caution 1. The above constants may be changed without notice.
2. The example of connection shown above and the constants do not guarantee proper operation.
Perform thorough evaluation using the actual application to set the constant.
3. The DP pin should be open.