8. Overcurrent 3 detection delay time (Overcurrent 3 detection function "available")
(Test condition 5, test circuit 5)
8. 1 Active "L"
The overcurrent 3 detection delay time (tDIOV3) is the time period from when the voltage V2 exceeds VDIOV3 to when
VDO goes to "L", after V2 is increased to 1.6 V instantaneously (within 10 μs) under the set conditions of V1 = 3.5 V,
V2 = 0 V.
8. 2 Active "H"
The overcurrent 3 detection delay time (tDIOV3) is the time period from when the voltage V2 exceeds VDIOV3 to when
VDO goes to "H", after V2 is increased to 1.6 V instantaneously (within 10 μs) under the set conditions of V1 =
3.5 V, V2 = 0 V.