English
Language : 

S-8211D Datasheet, PDF (18/36 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 1-CELL PACK
BATTERY PROTECTION IC FOR 1-CELL PACK
S-8211D Series
Rev.4.5_00
9. Delay Circuit
The detection delay times are determined by dividing a clock of approximately 3.5 kHz by the counter.
Remark1. The discharge overcurrent detection delay time (tDIOV) and the load short-circuiting detection delay time
(tSHORT) start when the discharge overcurrent detection voltage (VDIOV) is detected. When the load short-
circuiting detection voltage (VSHORT) is detected over the load short-circuiting detection delay time (tSHORT)
after the detection of discharge overcurrent detection voltage (VDIOV), the S-8211D turns the discharging
control FET off within tSHORT from the time of detecting VSHORT.
VDD
DO Pin
tD
VSS
Load short-circuiting detection delay time (tSHORT)
VDD
VM Pin
VSHORT
VDIOV
VSS
Figure 10
0 ≤ tD ≤ tSHORT
Time
Time
2. With shutdown function
When any overcurrent is detected and the overcurrent continues for longer than the overdischarge
detection delay time (tDL) without the load being released, the status changes to the power-down status at
the point where the battery voltage falls below overdischarge detection voltage (VDL).
When the battery voltage falls below overdischarge detection voltage (VDL) due to overcurrent, the S-
8211D Series turns the discharging control FET off via overcurrent detection. In this case, if the recovery
of the battery voltage is so slow that the battery voltage after the overdischarge detection delay time is
still lower than the overdischarge detection voltage, S-8211D Series shifts to the power-down status.
Without shutdown function
When any overcurrent is detected and the overcurrent continues for longer than the overdischarge
detection delay time (tDL) without the load being released, the status changes to the overdischarge status
at the point where the battery voltage falls below overdischarge detection voltage (VDL).
When the battery voltage falls below overdischarge detection voltage (VDL) due to overcurrent, the S-
8211D Series turns the discharging control FET off via overcurrent detection. In this case, if the recovery
of the battery voltage is so slow that the battery voltage after the overdischarge detection delay time is
still lower than the overdischarge detection voltage, S-8211D Series shifts to the overdischarge status.
18