3. Basic operation
This IC changes the output voltage level (VOUT) according to the level of the magnetic flux density (N pole or S pole)
applied by a magnet.
The following explains the operation when the magnetism detection logic is active "L".
3. 1 Product with both poles detection
When the magnetic flux density vertical to the marking surface exceeds the operation point (BOPN or BOPS) after
the S pole or N pole of a magnet is moved closer to the marking surface of this IC, VOUT changes from "H" to "L".
When the S pole or N pole of a magnet is moved further away from the marking surface of this IC and the
magnetic flux density is lower than the release point (BRPN or BRPS), VOUT changes from "L" to "H".
Figure 15 shows the relationship between the magnetic flux density and VOUT.
BHYSN
VOUT
BHYSS
H
N pole
BOPN
BRPN
0
BRPS
Magnetic flux density (B)
BOPS
L
S pole
Figure 15
3. 2 Product with S pole detection
When the magnetic flux density vertical to the marking surface exceeds BOPS after the S pole of a magnet is
moved closer to the marking surface of this IC, VOUT changes from "H" to "L". When the S pole of a magnet is
moved further away from the marking surface of this IC and the magnetic flux density is lower than BRPS, VOUT
changes from "L" to "H".
Figure 16 shows the relationship between the magnetic flux density and VOUT.
VOUT
BHYSS
H
N pole
0
BRPS
Magnetic flux density (B)
BOPS
Figure 16
L
S pole