English
Language : 

S-5712ANDL0-M3T1U Datasheet, PDF (13/30 Pages) Seiko Instruments Inc – LOW VOLTAGE OPERATION
LOW VOLTAGE OPERATION BOTH POLES / UNIPOLAR DETECTION TYPE HALL IC
Rev.4.6_00
S-5712 Series
3. Product with N pole detection
3. 1 Product with BOP = 1.8 mT typ.
Table 21
Item
Operation point*1
Release point*2
Hysteresis width*3
N pole
N pole
N pole
Symbol
BOPN
BRPN
BHYSN
(Ta = +25°C, VDD = 1.85 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
−3.0
−1.8
−0.6
mT
5
−
−2.4
−1.1
−0.1
mT
5
BHYSN = |BOPN − BRPN|
−
0.7
−
mT
5
3. 2 Product with BOP = 3.0 mT typ.
Table 22
Item
Operation point*1
Release point*2
Hysteresis width*3
N pole
N pole
N pole
Symbol
BOPN
BRPN
BHYSN
(Ta = +25°C, VDD = 1.85 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
−4.0
−3.0
−1.4
mT
5
−
−3.7
−2.2
−1.1
mT
5
BHYSN = |BOPN − BRPN|
−
0.8
−
mT
5
3. 3 Product with BOP = 4.5 mT typ.
Table 23
Item
Operation point*1
Release point*2
Hysteresis width*3
N pole
N pole
N pole
Symbol
BOPN
BRPN
BHYSN
(Ta = +25°C, VDD = 1.85 V, VSS = 0 V unless otherwise specified)
Condition
Min.
Typ.
Max. Unit Test Circuit
−
−6.0
−4.5
−2.5
mT
5
−
−5.5
−3.5
−2.0
mT
5
BHYSN = |BOPN − BRPN|
−
1.0
−
mT
5
*1. BOPN, BOPS: Operation points
BOPN and BOPS are the values of magnetic flux density when the output voltage (VOUT) changes after the magnetic flux
density applied to this IC by the magnet (N pole or S pole) is increased (by moving the magnet closer).
Even when the magnetic flux density exceeds BOPN or BOPS, VOUT retains the status.
*2. BRPN, BRPS: Release points
BRPN and BRPS are the values of magnetic flux density when the output voltage (VOUT) changes after the magnetic flux
density applied to this IC by the magnet (N pole or S pole) is decreased (the magnet is moved further away).
Even when the magnetic flux density falls below BRPN or BRPS, VOUT retains the status.
*3. BHYSN, BHYSS: Hysteresis widths
BHYSN and BHYSS are the difference between BOPN and BRPN, and BOPS and BRPS, respectively.
Remark The unit of magnetic density mT can be converted by using the formula 1 mT = 10 Gauss.
13