S-7760A Datasheet, PDF (16/53 Pages) Seiko Instruments Inc – PROGRAMMABLE PORT CONTROLLER (PORT EXPANDER WITH BUILT-IN E2PROM CIRCUIT) | |||
|
◁ |
PROGRAMMABLE PORT CONTROLLER (PORT EXPANDER WITH BUILT-IN E2PROM CIRCUIT)
S-7760A
Rev.1.3_00
In case that users select âdelay time option Aâ and to use an internal oscillation circuit, and if setting â1â in B6 bit in the
D03 timer setting register, â1â in TS3 in the timer scale register, DO3 inverts at delay time of 35 µs (7 à 5 µs). Other
examples are shown in Figure 18.
MSB
B7
B6
B5
B4
B3
B2
B1
B0
LSB
Example 1-1
40 µs
35 µs
30 µs
25 µs
20 µs
15 µs
10 µs
5 µs
Example 1-2 2.56 ms 2.24 ms 1.92 ms 1.60 ms 1.28 ms 0.96 ms 0.64 ms 0.32 ms
MSB
B7
B6
B5
B4
B3
B2
B1
B0
LSB
Example 2-1
160 µs
140 µs
120 µs
100 µs
80 µs
60 µs
40 µs
20 µs
Example 2-2 10.24 ms 8.96 ms 7.68 ms 6.40 ms 5.12 ms 3.84 ms 2.56 ms 1.28 ms
Example 1. When using an internal CLK
Example 1-1 In case of; Timer scale register â1â (short-time setting), Delay time option âAâ (Ã1 setting); (T = 5 µs)
Example 1-2 In case of; Timer scale register â0â (long-time setting), Delay time option âAâ (Ã1 setting); (LT = 320 µs)
Example 2. When using an external CLK (100 KHz, Tâ = 10 µs)
Example 2-1 In case of; Timer scale register â1â (short-time setting), Delay time option âBâ (Ã2 setting); (T = 2 à Tâ = 20 µs)
Example 2-2 In case of; Timer scale register â0â (long-time setting), Delay time option âBâ (Ã2 setting); (LT = 128 à Tâ = 1280 µs)
Figure 18 Example of Using Timer Setting Register 0 to 3
16
Seiko Instruments Inc.
|
▷ |