Rev.3.3_00
(2) Connection Example 2
RVCC
R1
BAT1
C1
SENSE VCC
CVCC
VC1
R2
BAT2
C2
VC2
R3
BAT3
C3
ICT
CICT
VC3
R4
BAT4
C4
FET
VSS
CO
EB+
EB-
Figure 8
SC PROTECTOR
Table 8 Constants for External Components 2
Symbol
Min.
Typ.
Max.
Unit
R1 to R4
0
1k
10 k
Ω
C1 to C4
0
0.1
1
µF
RVCC
0
100
1k
Ω
CVCC
0
0.1
1
µF
CICT
0
0.1
1
µF
Caution1.
2.
3.
The above constants may be changed without notice.
It has not been confirmed whether the operation is normal or not in circuits
other than the above example of connection. In addition, the example of
connection shown above and the constant do not guarantee proper operation.
Perform through evaluation using the actual application to set the constant.
In the case of Nch open drain output, pull up CO pin by external resistor.