English
Language : 

S1172 Datasheet, PDF (13/35 Pages) Seiko Instruments Inc – HIGH RIPPLE-REJECTION LOW DROPOUT
Rev.2.2_01
HIGH RIPPLE-REJECTION LOW DROPOUT HIGH OUTPUT CURRENT CMOS VOLTAGE REGULATOR
S-1172 Series
6.
Output voltage temperature coefficient
 ΔVOUT
ΔTa•VOUT


The shaded area in Figure 12 is the range where VOUT varies in the operation temperature range when the output
voltage temperature coefficient is ±130 ppm/°C.
VOUT [V]
Example of S-1172B30 typ. product
+0.39 mV/°C
VOUT(E)*1
−0.39 mV/°C
−40
+25
+85
Ta [°C]
*1. VOUT(E) is the value of the output voltage measured at Ta = +25°C.
Figure 12
A change in the temperature of the output voltage [mV/°C] is calculated using the following equation.
ΔVOUT
ΔTa
[mV/°C]*1 = VOUT(S) [V]*2 ×
ΔVOUT
ΔTa•VOUT
[ppm/°C]*3 ÷ 1000
*1. Change in temperature of output voltage
*2. Set output voltage
*3. Output voltage temperature coefficient
Seiko Instruments Inc.
13