English
Language : 

S1112 Datasheet, PDF (13/30 Pages) Seiko Instruments Inc – HIGH RIPPLE-REJECTION AND LOW DROPOUT
HIGH RIPPLE-REJECTION AND LOW DROPOUT CMOS VOLTAGE REGULATOR
Rev.6.1_00
S-1112/1122 Series
7. Output voltage temperature coefficient
 ΔVOUT
ΔTa • VOUT


The shaded area in Figure 11 is the range where VOUT varies in the operation temperature range when the
output voltage temperature coefficient is ±100 ppm/°C.
VOUT
[V]
Example of S-1112/1122B28 typ. product
+0.28 mV/°C
VOUT(E)*1
−0.28 mV/°C
−40
+25
+85
Ta [°C]
*1. VOUT(E) is the value of the output voltage measured at Ta = +25°C.
Figure 11
A change in the temperature of the output voltage [mV/°C] is calculated using the following equation.
ΔVOUT
ΔTa
[mV/°C]*1 = VOUT(S) [V]*2 ×
ΔVOUT
ΔTa • VOUT
[ppm/°C]*3 ÷ 1000
*1. Change in temperature of output voltage
*2. Set output voltage
*3. Output voltage temperature coefficient
Seiko Instruments Inc.
13