|
S-35399A02 Datasheet, PDF (11/55 Pages) Seiko Instruments Inc – 2-WIRE REAL-TIME CLOCK | |||
|
◁ |
Rev.1.0_00
2-WIRE REAL-TIME CLOCK
S-35399A02
2. Configuration of command
13 types of command are available for the S-35399A02, The S-35399A02 does Read/Write the various registers by
inputting these codes and commands. The S-35399A02 does not perform any operation with any codes and commands
other than those below.
Table 9 List of Command
Code
C2 C1 C0
Command
Description
Data
B7
B6
B5
B4
B3
B2
B1
B0
0 0 0 Status register 1 access
0 0 1 Status register 2 access
RESET*1 12/ 24 SC0*2 SC1*2 INT1*3 INT2*3 BLD*4 POC*4
INT1FE INT1ME INT1AE 32kE INT2FE INT2ME INT2AE TEST*5
Real-time data 1 access
0 1 0 (year data to)
0
1
1
Real-time data 2 access
(hour data to)
Y1
Y2
Y4
Y8 Y10 Y20 Y40 Y80
M1
M2
M4
M8 M10
â*6
â*6
â*6
D1
D2
D4
D8
D10 D20
â*6
â*6
W1
W2
W4
â*6
â*6
â*6
â*6
â*6
H1
H2
H4
H8
H10 H20 AM/ PM â*6
m1
m2
m4
m8 m10 m20 m40
â*6
s1
s2
s4
s8
s10 s20 s40
â*6
H1
H2
H4
H8
H10 H20 AM/ PM â*6
m1
m2
m4
m8 m10 m20 m40
â*6
s1
s2
s4
s8
s10 s20 s40
â*6
INT1 register access
W1 W2 W4
â*6
â*6
â*6
â*6 A1WE
0110
(alarm time 1: week/hour/minute)
(INT1AE = 1, INT1ME = 0,
H1
H2
H4
H8 H10 H20 AM/PM A1HE
1 0 0 INT1FE = 0)
m1 m2 m4 m8 m10 m20 m40 A1mE
INT1 register access
(output of user-set frequency)
(INT1ME = 0, INT1FE = 1)
1 Hz 2 Hz 4 Hz 8 Hz 16 Hz SC2 *2 SC3 *2 SC4 *2
INT2 register access
W1 W2 W4
â*6
â*6
â*6
â*6 A2WE
(alarm time 2: week/hour/minute)
(INT2AE = 1, INT2ME = 0,
H1
H2
H4
H8 H10 H20 AM/PM A2HE
1 0 1 INT2FE = 0)
m1 m2 m4 m8 m10 m20 m40 A2mE
INT2 register access
(output of user-set frequency)
(INT2ME = 0, INT2FE = 1)
1 Hz 2 Hz 4 Hz 8 Hz 16 Hz SC5 *2 SC6 *2 SC7 *2
1 1 0 Clock correction register access
V0
V1
V2
V3
V4
V5
V6
V7
1 1 1 Free register access
F0
F1
F2
F3
F4
F5
F6
F7
0 0 0 Up counter access *7
C64k C128k C256k C512k C1M C2M C4M C8M
C256 C512 C1k C2k C4k C8k C16k C32k
C1
C2
C4
C8 C16 C32 C64 C128
0 0 1 FOUT setting register 1 access 256 Hz 512 Hz 1 kHz 2 kHz 4 kHz 8 kHz 16 kHz 32 kHz
0111
01
10
0 FOUT setting register 2 access 1 Hz
Y1
0
Alarm expansion register 1 access
(alarm time 1 : year/month/day)
M1
D1
2 Hz
Y2
M2
D2
4 Hz
Y4
M4
D4
8 Hz
Y8
M8
D8
16 Hz
Y10
M10
D10
32 Hz
Y20
â*6
D20
64 Hz
Y40
A1YE
â*6
128 Hz
Y80
A1ME
A1DE
Y1
Y2
Y4
Y8 Y10 Y20 Y40 Y80
Alarm expansion register 2 access
10 1
M1
M2
M4
M8 M10
â*6 A2YE A2ME
(alarm time 2 : year/month/day)
D1
D2
D4
D8
D10 D20
â*6 A2DE
*1. Write-only flag. The S-35399A02 initializes by writing â1â in this register.
*2. Scratch bit. A R/W-enabled, user-free register.
*3. Read-only flag. Valid only when using the alarm function. When the alarm time matches, this flag is set to â1â, and it is
cleared to â0â when Read.
*4. Read-only flag. âPOCâ is set to â1â when power is applied. It is cleared to â0â when Read. Regarding âBLDâ, refer to âÂ
Low Power Supply Voltage Detection Circuitâ.
*5. Test bit for SII. Be sure to set â0â in use.
*6. No effect by Write. It is â0â when Read.
*7. The up counter is a Read-only register.
Seiko Instruments Inc.
11
|
▷ |