|
S8203A Datasheet, PDF (1/30 Pages) Seiko Instruments Inc – BATTERY PROTECTION IC FOR 3-SERIES CELL PACK | |||
|
S-8203A Series
www.sii-ic.com
© SII Semiconductor Corporation, 2016
BATTERY PROTECTION IC
FOR 3-SERIES CELL PACK
Rev.1.0_00
The S-8203A Series includes high-accuracy voltage detection circuits and delay circuits, in single use, makes it possible for
users to monitor the status of 3-series cell lithium-ion rechargeable battery.
The S-8203A Series is suitable for protecting lithium-ion rechargeable battery pack from overcharge, overdischarge, and
overcurrent.
ï® Features
⢠High-accuracy voltage detection function for each cell
Overcharge detection voltage n (n = 1 to 3)
3.55 V to 4.50 V*1 (50 mV step)
Overcharge release voltage n (n = 1 to 3)
3.30 V to 4.50 V*2
Overdischarge detection voltage n (n = 1 to 3)
2.0 V to 3.2 V*1 (100 mV step)
Overdischarge release voltage n (n = 1 to 3)
2.0 V to 3.4 V*3
Accuracy ±25 mV
Accuracy ±50 mV
Accuracy ±80 mV
Accuracy ±100 mV
⢠Discharge overcurrent detection in 2-step
Discharge overcurrent detection voltage
Short-circuiting detection voltage
0.05 V to 0.30 V*4 (50 mV step)
0.50 V to 1.0 V*4 (100 mV step)
Accuracy ±15 mV
Accuracy ±100 mV
⢠Charge overcurrent detection function
Charge overcurrent detection voltage
â0.30 V to â0.05 V (50 mV step) Accuracy ±30 mV
⢠Settable by external capacitor; overcharge detection delay time, overdischarge detection delay time, discharge
overcurrent detection delay time, charge overcurrent detection delay time
(Load short-circuiting detection delay time is internally fixed.)
⢠Independent charge and discharge control by the control pins
⢠Power-down function is selectable:
Available, unavailable
⢠High-withstand voltage:
Absolute maximum rating 28 V
⢠Wide operation voltage range:
2 V to 24 V
⢠Wide operation temperature range:
Ta = â40°C to +85°C
⢠Low current consumption
During operation:
40 μA max. (Ta = +25°C)
During power-down:
0.1 μA max. (Ta = +25°C)
⢠Lead-free (Sn 100%), halogen-free
*1. The overcharge detection voltage n (n = 1 to 3) and overdischarge detection voltage (n = 1 to 3) cannot be selected if
the voltage difference between them is 0.6 V or lower.
*2. Overcharge hysteresis voltage n (n = 1 to 3) can be selected as 0 V or from a range of 0.1 V to 0.4 V in 50 mV step.
(Overcharge hysteresis voltage = Overcharge detection voltage â Overcharge release voltage)
*3. Overdischarge hysteresis voltage n (n = 1 to 3) can be selected as 0 V or from a range of 0.2 V to 0.7 V in 100 mV
step.
(Overdischarge hysteresis voltage = Overdischarge release voltage â Overdischarge detection voltage)
*4. The discharge overcurrent detection voltage and load short-circuiting detection voltage cannot be selected if the
voltage difference between them is 0.3 V or lower.
ï® Application
⢠Rechargeable lithium-ion battery pack
ï® Package
⢠16-Pin TSSOP
1
|
▷ |