AATIAN76 Datasheet, PDF (6/8 Pages) SiGe Semiconductor, Inc. – Dual Slew Rate Controlled Load Switch
EV-140
AAT4282A EVAL:
Dual Slew Rate Controlled Load Switch
Test: Output Pull Down Impedance at Shutdown as Shown in Figure 3.
1. Remove JP1 jumper, set INA to 5V, set ENA and ENB to 0V to disable both channels.
2. Connect Keithley V/I source between OUTA and GND, set the voltage pulse to 1V with 5ms pulse width,
the compliance set to 100mA (the two sensing output wires need to connect as close as possible to the
OUTA and GND pins.)
3. Determine the output pull down impedance of channel A by taking the ratio of OUTA voltage and the sink-
ing current 100mA,
RDS(ON) =
VDS
IDS
.
4. Repeat the above steps for channel B output pull down impedance.
Figure 5: AAT4282A Evaluation Board Connection Diagram for Output Impedance Test.
6
EV-140.2007.08.1.0