English
Language : 

3RH19211CA10 Datasheet, PDF (69/76 Pages) Siemens Semiconductor Group – Contactors with Extended Tolerance 0.7 ... 1.25 x , for Railway Applications
Accessories and Spare Parts
For 3T Contactors and Contactor Relays
■ Selection and ordering data
Version
Rated control supply DT Order No.
voltage Us
AC
DC
V
V
Surge suppressors1) for 3TH4 contactor relays
Noise suppression diodes --
With line spacer, for mounting
onto the coil terminal
24 ... 250 A
3TX7 402-3.
Diode assemblies
--
24 ... 250 A
(diode and Zener diode) with
line spacer,
DC operation, for mounting
onto the coil terminal
Varistors2)
24 ... 48 24 ... 70 A
With line spacer, for mounting 48 ... 127 70 ... 150 A
onto the coil terminal
127 ... 240 150 ... 250 A
240 ... 400 --
C
400 ... 600 --
C
RC elements
24 ... 48 24 ... 70 A
With line spacer, for mounting 48 ... 127 70 ... 150 A
onto the coil terminal
127 ... 240 150 ... 250 A
240 ... 400 --
C
400 ... 600 --
C
Covers
--
--
B
For switch position indicator
Coupling links for control by PLC for 3TH4 contactor relays
Operating range: 17 ... 30 V DC
Power consumption: 0.5 W at 24 V DC
For mounting directly to contactor coil
A
without surge suppressor
For mounting directly to contactor coil
A
with surge suppressor
3TX7 402-3A
3TX7 402-3D
3TX7 402-3G
3TX7 402-3H
3TX7 402-3J
3TX7 402-3K
3TX7 402-3L
3TX7 402-3R
3TX7 402-3S
3TX7 402-3T
3TX7 402-3U
3TX7 402-3V
3TX4 210-0P
3TX4 090-0C
3TX4 090-0D
Accessories for 3TH contactor relays
Price PU
PS*
PG
per PU (UNIT,
SET, M)
Weight
per PU
approx.
kg
1 1 unit
101 0.147
1 1 unit
101 0.015
1 1 unit
1 1 unit
1 1 unit
1 1 unit
1 1 unit
1 1 unit
1 1 unit
1 1 unit
1 1 unit
1 1 unit
1 1 unit
101 0.015
101 0.015
101 0.015
101 0.024
101 0.024
101 0.025
101 0.025
101 0.023
101 0.024
101 0.024
101 0.002
1 1 unit
1 1 unit
101 0.055
101 0.057
3TX4 090
mounted to contactor
1) The opening delay of the NO contact and the closing delay of the
NC contact are increased if the contactor coils are attentuated against
voltage peaks (noise suppression diode 6 to 10 times; diode assemblies
2 to 6 times, varistor +2 to 5 ms).
2) Includes the peak value of the ripple voltage on the DC side.
For
contactor
Type
ON-delay devices
3TH42/
3TH43
Version
Rated control Time
DT Order No.
supply voltage range
Us AC 50/60 Hz (minimum
times)
V
s
NTC thermistors 220 ... 230
0.1
Time tolerance
+ 100 %, -50 %
B 3TX4 180-0A
Price PU
PS*
PG
Weight
per PU (UNIT,
per PU
SET, M)
approx.
kg
1 1 unit
101 0.013
3TX4 180-0A
* You can order this quantity or a multiple thereof.
Siemens LV 1 · 2006 3/139