English
Language : 

3RH19211CA10 Datasheet, PDF (47/76 Pages) Siemens Semiconductor Group – Contactors with Extended Tolerance 0.7 ... 1.25 x , for Railway Applications
Accessories and Spare Parts
For 3RT, 3RH Contactors and Contactor Relays
Accessories for 3RT, 3RH contactors and
contactor relays
For con- Auxiliary
tactors contacts
Rated control supply Time setting DT Order No.
voltage Us1)
range t
Price
per PU
Type
V
s
Solid-state time-delay auxiliary switch blocks,
for snapping onto the front, terminal designations
according to DIN 46199, Part 5
Size S00
3RT19 16-2....
3RT1. 1,
3RH112)
3RH14
3RT1. 1,
3RH112)
3RH14
ON-delay (varistor integrated)
1 NO + 1 NC 24 AC/DC3)
0.05 ... 1
0.5 ... 10
5 ... 100
} 3RT19 16-2EJ11
} 3RT19 16-2EJ21
B 3RT19 16-2EJ31
100 ... 127 AC3)
0.05 ... 1
0.5 ... 10
5 ... 100
C 3RT19 16-2EC11
} 3RT19 16-2EC21
} 3RT19 16-2EC31
200 ... 240 AC3)
0.05 ... 1
0.5 ... 10
5 ... 100
D 3RT19 16-2ED11
} 3RT19 16-2ED21
} 3RT19 16-2ED31
OFF-delay without auxiliary voltage (varistor integrated)4)
1 NO + 1 NC 24 AC/DC3)
0.05 ... 1
0.5 ... 10
5 ... 100
} 3RT19 16-2FJ11
} 3RT19 16-2FJ21
} 3RT19 16-2FJ31
100 ... 127 AC/DC3) 0.05 ... 1
0.5 ... 10
5 ... 100
D 3RT19 16-2FK11
} 3RT19 16-2FK21
B 3RT19 16-2FK31
200 ... 240 AC/DC3) 0.05 ... 1
0.5 ... 10
5 ... 100
D 3RT19 16-2FL11
} 3RT19 16-2FL21
} 3RT19 16-2FL31
OFF-delay with auxiliary voltage
3RT10 1 1 CO
3RH11
24 AC/DC
100 ... 127 AC
200 ... 240 AC
0.5 ... 10
0.5 ... 10
0.5 ... 10
B 3RT19 16-2LJ21
B 3RT19 16-2LC21
B 3RT19 16-2LD21
Wye-delta function (varistor integrated)
3RT10 12) 1 NO
24 AC/DC3)
delayed + 100 ... 127 AC3)
1 NO, instan- 200 ... 240 AC3)
1.5 ... 30
1.5 ... 30
1.5 ... 30
taneous,
dead time
50 ms
} 3RT19 16-2GJ51
D 3RT19 16-2GC51
} 3RT19 16-2GD51
Sizes S0 ... S12
3RT19 26-2....
3RT10,
3RT13,
3RT14,
3RT15
3RT10,
3RT13,
3RT14,
3RT15
With ON-delay
1 NO + 1 NC 24 AC/DC5)
0.05 ... 1
0.5 ... 10
5 ... 100
100 ... 127 AC5)
0.05 ... 1
0.5 ... 10
5 ... 100
200 ... 240 AC5)
0.05 ... 1
0.5 ... 10
5 ... 100
OFF-delay without auxiliary voltage4)
1 NO + 1 NC 24 AC/DC5)
0.05 ... 1
0.5 ... 10
5 ... 100
100 ... 127 AC/DC5) 0.05 ... 1
0.5 ... 10
5 ... 100
200 ... 240 AC/DC5) 0.05 ... 1
0.5 ... 10
5 ... 100
D 3RT19 26-2EJ11
} 3RT19 26-2EJ21
A 3RT19 26-2EJ31
C 3RT19 26-2EC11
} 3RT19 26-2EC21
D 3RT19 26-2EC31
D 3RT19 26-2ED11
} 3RT19 26-2ED21
B 3RT19 26-2ED31
} 3RT19 26-2FJ11
} 3RT19 26-2FJ21
} 3RT19 26-2FJ31
D 3RT19 26-2FK11
} 3RT19 26-2FK21
C 3RT19 26-2FK31
D 3RT19 26-2FL11
A 3RT19 26-2FL21
A 3RT19 26-2FL31
3RT10,
3RT13,
3RT14,
3RT15
Wye-delta function
1 NO,
24 AC/DC5)
delayed +
1 NO, instan-
taneous,
100 ... 127 AC5)
200 ... 240 AC5)
dead time
50 ms
1.5 ... 30
1.5 ... 30
1.5 ... 30
} 3RT19 26-2GJ51
} 3RT19 26-2GC51
} 3RT19 26-2GD51
PU PS*
(UNIT,
SET, M)
PG Weight
per PU
approx.
kg
1 1 unit 101 0.085
1 1 unit 101 0.084
1 1 unit 101 0.086
1 1 unit 101 0.087
1 1 unit 101 0.087
1 1 unit 101 0.086
1 1 unit 101 0.088
1 1 unit 101 0.089
1 1 unit 101 0.090
1 1 unit 101 0.087
1 1 unit 101 0.088
1 1 unit 101 0.089
1 1 unit 101 0.086
1 1 unit 101 0.087
1 1 unit 101 0.088
1 1 unit 101 0.089
1 1 unit 101 0.089
1 1 unit 101 0.089
1 1 unit 101 0.083
1 1 unit 101 0.085
1 1 unit 101 0.085
1 1 unit 101 0.086
1 1 unit 101 0.087
1 1 unit 101 0.090
1 1 unit 101 0.081
1 1 unit 101 0.081
1 1 unit 101 0.082
1 1 unit 101 0.083
1 1 unit 101 0.083
1 1 unit 101 0.083
1 1 unit 101 0.085
1 1 unit 101 0.085
1 1 unit 101 0.085
1 1 unit 101 0.085
1 1 unit 101 0.084
1 1 unit 101 0.085
1 1 unit 101 0.087
1 1 unit 101 0.086
1 1 unit 101 0.087
1 1 unit 101 0.086
1 1 unit 101 0.084
1 1 unit 101 0.086
1 1 unit 101 0.084
1 1 unit 101 0.085
1 1 unit 101 0.088
1) The AC voltages are valid for 50 Hz and 60 Hz.
2) Cannot be fitted onto coupling relays.
3) The terminals for the control supply voltage are connected to the
contactor by the integrated spring contacts of the solid-state time
auxiliary switch above it when this switch is mounted
4) Setting of output contacts in as-supplied state not defined (bistable relay).
Application of the control supply voltage once results in contact
changeover to the correct setting.
5) Terminals A1 and A2 for the control supply voltage of the solid-state time-
delay auxiliary switch must be connected to the associated contactor by
means of connecting leads.
* You can order this quantity or a multiple thereof.
Siemens LV 1 · 2006 3/117