English
Language : 

TDA4320X Datasheet, PDF (6/16 Pages) Siemens Semiconductor Group – FM-IF with Counter Output, Field Strength Indicator, Noise Detector and MUTE Setting
TDA 4320X
4
Electrical Characteristics
4.1 Absolute Maximum Ratings
TA = – 40 °C to + 85 °C
Parameter
Symbol
Supply voltage
Junction temperature
Storage temperature
Thermal resistance (system-air)
ESD voltage, HBM (1.5 kΩ, 100 pF)
VS
Tj
TS
RthSA
VESD
Limit Values
min. max.
0
13.2
150
125
105
–4 4
Unit
V
°C
°C
K/W
kV
Remarks
Note: Maximum ratings are absolute ratings; exceeding only one of these values may
cause irreversible damage to the integrated circuit.
4.2 Operating Range
TA = – 40 °C to + 85 °C
Parameter
Supply voltage
Ambient temperature
Symbol
VS
TA
Limit Values Unit
min. max.
7.5 13.2 V
– 40 85
°C
Remarks
Note: In the operating range the functions given in the circuit description are fulfilled.
Semiconductor Group
40
04.96