English
Language : 

TDA4320X Datasheet, PDF (12/16 Pages) Siemens Semiconductor Group – FM-IF with Counter Output, Field Strength Indicator, Noise Detector and MUTE Setting
Diagrams
Diagram D1
TDA 4320X
VF Dynamics
The dynamic range of VF voltage is determined by the test points M1 through M4 as
follows:
M1: test point (at ViIF = – 60 dBm) supplies VF(M1)
M2: test point (at ViIF = – 20 dBm) supplies VF(M2)
M3: test point (at ViIF = – 90 dBm) supplies VF(M3)
M4: test point (at ViIF = + 5 dBm) supplies VF(M4)
Hence follows:
MVF max := – 20 dBm + (VF(M4) – VF(M2))/(VF(M2) – VF(M1)) × 40 dB
MVF min := – 60 dBµV – (VF(M1) – VF(M3))/(VF(M2) – VF(M1)) × 40 dB
V M M = – F Dynamics
VF max
VF min
Semiconductor Group
46
04.96