English
Language : 

PSB7115 Datasheet, PDF (229/264 Pages) Siemens Semiconductor Group – Enhanced ISDN Data Access Controller ISAR 34
PSB 7115
Operational Description
3.13.4 Fax Pump Startup Procedure
The host configures the fax pump either as originator or answerer when a physical
connection has been established. After initialisation, the fax pump responds with
RSP_READY, indicating, that it is ready for the next procedure.
At this point the host must issue either a command CMD_FRH or CMD_FTH depending
upon if the host is answering or originating a facsimile connection. The interaction of the
host and the faxpump is as shown in the flow charts for transmission and reception of
HDLC and binary data.
ATA or ATD
Establish
physical connection,
Configure pump to
Fax Originator/Answerer
Event
RSP_READY
No
?
Yes
Proceed as with
"AT+FTH=3"
IF ANSWERER, or
"AT+FRH=3"
IF ORIGINATOR
No
Abort character
from DTE
?
Yes
Generate Command
CMD_HALT
Teardown
physical connection
7115_51
Issue
"OK"
Done
Figure 57 Fax Class 1 - Startup Procedure
Semiconductor Group
229
02.98