English
Language : 

SGS4-S076P3PS1T00 Datasheet, PDF (8/9 Pages) SICK AG – SWITCHING AUTOMATION LIGHT GRIDS
SGS4-S076P3PS1T00 | SLG
SWITCHING AUTOMATION LIGHT GRIDS
A
B
C
D
E
F
1. Light grid in RUN mode,
green LED “ON”
illuminates, yellow LED
“Q” illuminates.
1
2
3
ON
Q
Func
1 s ... 5 s
2. Alignment aid is
automatically activated
for 10 s.
1
2
3
ON
Q
Func
1
2
3
ON
Q
Func
1
2
3
ON
Q
Func
123
3. Light grid in RUN mode,
green LED “ON”
illuminates, yellow LED
“Q” illuminates.
1
2
3
ON
Q
Press the teach button for
1 s to 5 s. During the teach
process the green LEDs
illuminates sequentially. The
red LED “Func” illuminates.
1 = Optimum light reception.
2 = Light reception not optimized,
➜ align sensors.
3 = No light received,
➜ check light path.
The light grid switches after
10 s automatically back into
the RUN mode.
The switching threshold is set.
H
I
J
K
L
M
N
O
P
Q
R
S
T
Funktionsprinzip
Slim & Flat
1
2
① Slim model = light emission on narrow side
② Flat model = light emission on broad side
Recommended accessories
Other models and accessories www.sick.de/SLG
Brief description
Mounting brackets and mounting plates
Mounting bracket for light grids up to a monitoring height of 600 mm, mounting on the
face sides, 2x BEF-SLG1, 2x BEF-SLG2
Plug connectors and cables
Head A: female connector, M8, 4-pin, straight
Head B: cable
Cable: PVC, unshielded, 2 m
Type
BEF-SLG-SET1
DOL-0804-G02M
Part no.
2055427
6009870
8
AUTOMATION LIGHT GRIDS | SICK
Online data sheet | 2016-03-09 17:40:10
Subject to change without notice