English
Language : 

SKS36S-HVA0-K02 Datasheet, PDF (3/7 Pages) SICK AG – MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE
SKS36S-HVA0-K02 | SKS/SKM36
MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE®
Electrical data
Supply voltage range
Recommended supply voltage
Operating power consumption (no load)
Output frequency for sine/cosine signals
7 V DC ... 12 V DC
8 V DC
≤ 60 mA 1)
0 kHz ... 65 kHz
1) Without load.
Mechanical data
Shaft version
Flange type/stator coupling
Dimensions
Weight
Moment of inertia of the rotor
Operating speed
Angular acceleration
Operating torque
Start up torque
Permissible Load capacity of shaft
Life of ball bearings
Connection type
Solid shaft
Servo-/face mount flange / stator coupling
See dimensional drawing
0.07 kg
6 gcm²
12,000 U/min
≤ 500,000 rad/s²
0.6 Ncm
0.9 Ncm
10 N (radial)
5 N (axial)
2.0 x 10^9 revolutions
Male connector M12, 8-pin, radial
Ambient data
Operating temperature range
–20 °C ... +100 °C
Storage temperature range
–40 °C ... +125 °C, without package
Relative humidity/condensation
90 %, Condensation not permitted
Resistance to shocks
100 g, 6 ms, 6 ms (according to EN 60068-2-27)
Frequency range of resistance to vibrations 50 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
EMC
According to EN 61000-6-2 and EN 61000-6-3
Enclosure rating
IP50, with mating connector inserted (according to IEC 60529)
Classifications
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
27270590
27270590
27270590
27270590
27270590
27270590
27270590
27270590
EC001486
EC001486
41112113
2017-05-10 11:53:11 | Online data sheet
S ubject to change without notice
MOTOR FEEDBACK SYSTEMS | SICK