English
Language : 

SKS36S-HVA0-K02 Datasheet, PDF (2/7 Pages) SICK AG – MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE
SKS36S-HVA0-K02 | SKS/SKM36
MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE®
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
SKS36S-HVA0-K02
Other models and accessories www.sick.com/SKS_SKM36
Part no.
1036557
Illustration may differ
Detailed technical data
Safety-related parameters
Safety integrity level
Category
Performance level
PFHD: Probability of dangerous failure per
hour
TM (mission time)
MTTFd: mean time to dangerous failure
SIL2 (IEC 61508), SILCL2 (IEC 62061)
3 (EN ISO 13849)
PL d (EN ISO 13849) 1)
1.3 x 10-8 2)
20 years (EN ISO 13849)
874 years (EN ISO 13849)
1) For more detailed information on the exact configuration of your machine/unit, please consult your relevant SICK branch office.
2) The values displayed apply to a diagnostic degree of coverage of 90%, which must be achieved by the external drive system.
Performance
Number of sine/cosine periods per revolu- 128
tion
Number of the absolute ascertainable revo- 1
lutions
Total number of steps
4,096
Measuring step
2.5 Winkelsekunden For interpolation of the sine/cosine signals with, e. g., 12 bits
Integral non-linearity typ.
± 120 Winkelsekunden, Error limits for evaluating sine/cosine period
Differential non-linearity
Non-linearity within a sine/cosine period
Operating speed
6,000 min⁻¹, up to which the absolute position can be reliably produced
Interfaces
Type of code for the absolute value
Code sequence
Communication interface
Available memory area
Binary
Increasing, when turning the shaft For clockwise rotation, looking in direction “A” (see dimen-
sional drawing), for clockwise shaft rotation, looking in direction "A" (see dimensional drawing)
HIPERFACE®
1,792 Byte
2
MOTOR FEEDBACK SYSTEMS | SICK
Online data sheet | 2017-05-10 11:53:11
Subject to change without notice