English
Language : 

SKM36-HFA0-K02 Datasheet, PDF (3/7 Pages) SICK AG – MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE
SKM36-HFA0-K02 | SKS/SKM36
MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE®
Start up torque
0.3 Ncm
Permissible shaft movement, radial, static ± 0.1 mm
Permissible shaft movement, radial, dynam- ± 0.05 mm
ic
Permissible shaft movement, axial, static –0.4 mm, 0.2 mm
Permissible shaft movement, axial, dynamic ± 0.1 mm
Life of ball bearings
3.6 x 10^9 revolutions
Connection type
Male connector M12, 8-pin, radial
Ambient data
Operating temperature range
–20 °C ... +110 °C
Storage temperature range
–40 °C ... +125 °C, without package
Relative humidity/condensation
90 %, Condensation not permitted
Resistance to shocks
100 g, 6 ms, 6 ms (according to EN 60068-2-27)
Frequency range of resistance to vibrations 50 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
EMC
According to EN 61000-6-2 and EN 61000-6-3 1)
Enclosure rating
IP50, with mating connector inserted and closed cover (according to IEC 60529)
1) The EMC according to the standards quoted is achieved when the motor feedback system is mounted in an electrically conductive housing, which is connected to
the central earthing point of the motor controller via a cable screen. The GND (0V) connection of the supply voltage is also grounded here. If other screening concepts
are used, users must perform their own tests.
Classifications
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
27270590
27270590
27270590
27270590
27270590
27270590
27270590
27270590
EC001486
EC001486
41112113
2017-05-10 11:53:11 | Online data sheet
S ubject to change without notice
MOTOR FEEDBACK SYSTEMS | SICK
3