English
Language : 

SEK90-HN050AK02 Datasheet, PDF (3/7 Pages) SICK AG – MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE
SEK90-HN050AK02 | SEK90
MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE®
Weight
0.13 kg
Moment of inertia of the rotor
340 gcm²
Operating speed
3,000 min⁻¹
Angular acceleration
≤ 50,000 rad/s²
Permissible shaft movement, radial, static ± 0.2 mm
Permissible shaft movement, radial, dynam- ± 0.05 mm
ic
Permissible axial shaft movement
± 0.5 mm 1)
Connection type
Male connector M12, 8-pin
1) Relative to the installation position, as described in the assembly instructions (order nr. 8013609) and in the proposed customer fitting.
Ambient data
Operating temperature range
–30 °C ... +115 °C
Storage temperature range
–50 °C ... +125 °C, without package
Relative humidity/condensation
90 %, Condensation not permitted
Resistance to shocks
100 g, 6 ms (according to EN 60068-2-27)
Frequency range of resistance to vibrations 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6)
EMC
According to EN 61000-6-2 and EN 61000-6-3 1)
Enclosure rating
IP40, with mating connector inserted and closed cover (according to IEC 60529)
1) The EMC according to the standards quoted is achieved when the motor feedback system is mounted in an electrically conductive housing, which is connected to
the central earthing point of the motor controller via a cable shield. Users must perform their own tests when other shield designs are used.
Classifications
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
UNSPSC 16.0901
27270590
27270590
27270590
27270590
27270590
27270590
27270590
27270590
EC001486
EC001486
41112113
2017-05-10 11:53:11 | Online data sheet
S ubject to change without notice
MOTOR FEEDBACK SYSTEMS | SICK
3