English
Language : 

SEK90-HN050AK02 Datasheet, PDF (2/7 Pages) SICK AG – MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE
SEK90-HN050AK02 | SEK90
MOTOR FEEDBACK SYSTEMS ROTARY HIPERFACE®
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
SEK90-HN050AK02
Other models and accessories www.sick.com/SEK90
Part no.
1038271
Illustration may differ
Detailed technical data
Features
Specialty
Stranded cable with strain relief not included in scope of delivery, please order separately
(partnumer 2051662), resolver support, plug-in shaft
Performance
Number of sine/cosine periods per revolu- 64
tion
Number of the absolute ascertainable revo- 1
lutions
Total number of steps
2,048 via RS485
Measuring step
5 Winkelsekunden For interpolation of the sine/cosine signals with, e. g., 12 bits
Integral non-linearity typ.
± 72 Winkelsekunden, Error limits for evaluating sine/cosine period, Typical values for nominal
position ± 0.1 mm and + 20 °C
Differential non-linearity
± 45 Winkelsekunden, Non-linearity within a sine/cosine period, Typical values for nominal po-
sition ± 0.1 mm and + 20 °C
Operating speed
3,000 min⁻¹, up to which the absolute position can be reliably produced
Latency
100 µs
Interfaces
Type of code for the absolute value
Code sequence
Communication interface
Available memory area
Binary
Increasing, when turning the shaft For clockwise rotation, looking in direction “A” (see dimen-
sional drawing), for clockwise shaft rotation, looking in direction "A" (see dimensional drawing)
HIPERFACE®
1,792 Byte
Electrical data
Supply voltage range
Recommended supply voltage
Operating power consumption (no load)
7 V DC ... 12 V DC
8 V DC
≤ 150 mA 1)
1) Without load.
Mechanical data
Shaft version
Dimensions
Through hollow shaft
See dimensional drawing
1) Relative to the installation position, as described in the assembly instructions (order nr. 8013609) and in the proposed customer fitting.
2
MOTOR FEEDBACK SYSTEMS | SICK
Online data sheet | 2017-05-10 11:53:11
Subject to change without notice