English
Language : 

OD5-150T40 Datasheet, PDF (3/6 Pages) SICK AG – DISPLACEMENT MEASUREMENT SENSORS
Ambient data
Enclosure rating
Protection class
Ambient temperature
Relative air humidity (non-condensing)
Temperature drift
Typ. Ambient light immunity
Vibration resistance
Shock resistance
OD5-150T40 | OD Precision
DISPLACEMENT MEASUREMENT SENSORS
IP 67
III
Operation: –10 °C ... +50 °C
Storage: –20 °C ... +60 °C
35 % ... 85 %
± 0.01 % FS/K (FS = Full Scale = Measuring range of sensor)
Artificial light: ≤ 3,000 lx
Sunlight: ≤ 10,000 lx
10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
50 G (x, y, z axis 3 times each)
Dimensional drawing (Dimensions in mm (inch))
OD5-150xx
76.5 (3.01)
75 (2.95)
1.5
(0.06)
4.2
(0.17)
27 (1.06)
2
3
1
2 x M4
Ø 7.1
(0.28)
① Cable Ø 7.1 mm, 0.5 m with connector, 12-pin
② Optical axis receiver
③ Optical axis sender
Connection type
Hirose 12-pin male connector for sensor head
2016-03-17 13:18:11 | Online data sheet
S ubject to change without notice
DISTANCE SENSORS | SICK
3