English
Language : 

OD5-150T40 Datasheet, PDF (2/6 Pages) SICK AG – DISPLACEMENT MEASUREMENT SENSORS
OD5-150T40 | OD Precision
DISPLACEMENT MEASUREMENT SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
OD5-150T40
Other models and accessories www.sick.com/OD_Precision
Part no.
6049579
Detailed technical data
Features
System part
Performance
Sensor head
Measuring range
Resolution
Repeatability
Linearity
Response time
Measuring frequency
Light source
Laser class
Typ. light spot size (distance)
Note
110 mm ... 190 mm, 6 % ... 90 % remission; at default settings
2 µm 1)
6 µm 1)
± 40 µm 1)
0.1 ms 2) 3)
10 kHz 3)
Laser, red
2 (EN 60825-1) 4)
Ø 180 µm (150 mm)
OD Precision sensor head is compatible with AOD5 hardware version 1.7. and software version
4.3 (correspond with production date from Lot 1338)
1) Measurement at 90% remission (ceramic, white), or mirror for OD5-25x; averaging set to: 256 or 4096 for OD5-25x; constant ambient conditions.
2) Time needed for automatic sensitivity adjustment is calculated as: sampling period x 20. At default setting 100 µs (10kHz) this is <= 2ms.
3) Default setting for OD5-350x100 and OD5-500x200 = 0.8 ms, or 1.25 kHz, all others = 0.1 ms/10 kHz.
4) Wavelength: 655 nm, max. output: 1 mW.
Interfaces
Laser-off input
Data interface
Mechanics/electronics
1 x laser-off
RS-422
Supply voltage Vs
Warm-up time
Housing material
Connection type
Indication
Weight
DC 12 V ... 24 V 1)
≤ 5 min
Aluminum housing with glass lens
0.5 m cable with connector 2)
LEDs, 4'' color display on optional evaluation unit
250 g 3)
1) DC 12 V (–5 %) ... DC 24 V (+10 %)
2) Can be extended to up to 50 m with extension cable.
3) Includes 0.5 m cable.
2
DISTANCE SENSORS | SICK
Online data sheet | 2016-03-17 13:18:11
Subject to change without notice