English
Language : 

FFUS15-1G1IO Datasheet, PDF (3/5 Pages) SICK AG – FLOW SENSORS
FFUS15-1G1IO | FFU
FLOW SENSORS
Output signal
Output current
Output load
Lower signal level
Upper signal level
Impuls/frequency output
Puls width
Signal voltage HIGH
Signal voltage LOW
Inductive load
Capacitive load
Response time
Analog output 4 mA ... 20 mA, 0 mA ... 20 mA current flow and temperature, 1 pulse/status
output PNP/NPN-transistor output for flow rate meter, empty pipe detection, flow monitoring,
dosing output, flow direction (dependent on type) 1)
< 100 mA 4)
< 500 Ohm
3.8 mA ... 4 mA
20 mA ... 20.5 mA
0 kHz ... 10 kHz
≤1s
Vs - 2 V
≤2V
1H
100 nF
Filter off 100 ms, filter low 300 ms, filter medium 1 s, filter strong 4.2 s 5)
1) All connections are polarity protected. All outputs are overload and short-circuit protected.
2) May not exceed or fall below Uv tolerances.
3) Without load.
4) There are 100 mA for each output pnp and npn available.
5) Analog output and display.
Mechanics
Process connection
Wetted parts
Housing material
Enclosure rating
Weight
G¾
PPSU
PPSU
IP 67
350 g
Ambient data
Ambient operating temperature
Ambient storage temperature
0 °C ... +60 °C
–20 °C ... +70 °C
Classifications
ECl@ss 5.0
ECl@ss 5.1.4
ECl@ss 6.0
ECl@ss 6.2
ECl@ss 7.0
ECl@ss 8.0
ECl@ss 8.1
ECl@ss 9.0
ETIM 5.0
ETIM 6.0
27371815
27371815
27371815
27371815
27371815
27371815
27371815
27371815
EC002580
EC002580
2017-02-08 13:58:08 | Online data sheet
S ubject to change without notice
FLUID SENSORS | SICK
3