Electrical Characteristics (TJ=25°C unless otherwise noted)
Symbol
Parameter
Conditions
Min
STATIC PARAMETERS
BVDSS Drain-Source Breakdown Voltage
IDSS
Zero Gate Voltage Drain Current
IGSS
VGS(th)
ID(ON)
Gate-Body leakage current
Gate Threshold Voltage
On state drain current
ID=250µA, VGS=0V
VDS=16V, VGS=0V
VDS=0V, VGS=±12V
VDS=VGS ID=250µA
VGS=4.5V, VDS=5V
VGS=10V, ID=8A
RDS(ON)
gFS
VSD
IS
Static Drain-Source On-Resistance
VGS=4.5V, ID=5A
VGS=2.5V, ID=4A
VGS=1.8V, ID=3A
Forward Transconductance
VDS=5V, ID=8A
Diode Forward Voltage
IS=1A,VGS=0V
Maximum Body-Diode Continuous Current
20
TJ=55°C
0.5
30
TJ=125°C
DYNAMIC PARAMETERS
Ciss
Input Capacitance
Coss
Output Capacitance
Crss
Reverse Transfer Capacitance
Rg
Gate resistance
VGS=0V, VDS=10V, f=1MHz
VGS=0V, VDS=0V, f=1MHz
SWITCHING PARAMETERS
Qg
Total Gate Charge
Qgs
Gate Source Charge
Qgd
Gate Drain Charge
tD(on)
Turn-On DelayTime
tr
Turn-On Rise Time
tD(off)
Turn-Off DelayTime
tf
Turn-Off Fall Time
trr
Body Diode Reverse Recovery Time
Qrr
Body Diode Reverse Recovery Charge
VGS=4.5V, VDS=10V, ID=8A
VGS=10V, VDS=10V, RL=1.3Ω,
RGEN=3Ω
IF=8A, dI/dt=100A/µs
IF=8A, dI/dt=100A/µs
Typ
0.75
10.6
14.2
12.2
16.1
23.2
36
0.73
1810
232
200
1.6
19.8
1.8
5
3.3
5.9
44
7.7
22
9.8
Max Units
V
10
µA
25
100 nA
1
V
A
14
mΩ
17
15 mΩ
20 mΩ
28 mΩ
S
1
V
2.4
A
pF
pF
pF
Ω
nC
nC
nC
ns
ns
ns
ns
ns
nC
A: The value of RθJA is measured with the device mounted on 1in2 FR-4 board with 2oz. Copper, in a still air environment with TA =25°C. The
value in any given application depends on the user's specific board design. The current rating is based on the t≤ 10s thermal resistance rating.
B: Repetitive rating, pulse width limited by junction temperature.
C. The R θJA is the sum of the thermal impedence from junction to lead RθJL and lead to ambient.
D. The static characteristics in Figures 1 to 6,12,14 are obtained using 80µs pulses, duty cycle 0.5% max.
E. These tests are performed with the device mounted on 1 in2 FR-4 board with 2oz. Copper, in a still air environment with TA=25°C. The SOA
curve provides a single pulse rating.
Rev3: August 2005
THIS PRODUCT HAS BEEN DESIGNED AND QUALIFIED FOR THE CONSUMER MARKET. APPLICATIONS OR USES AS CRITICAL
COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS ARE NOT AUTHORIZED. AOS DOES NOT ASSUME ANY LIABILITY ARISING
OUT OF SUCH APPLICATIONS OR USES OF ITS PRODUCTS. AOS RESERVES THE RIGHT TO IMPROVE PRODUCT DESIGN,
FUNCTIONS AND RELIABILITY WITHOUT NOTICE.