English
Language : 

GP2D150AJ00F Datasheet, PDF (3/9 Pages) Sharp Electrionic Components – Factory set trigger point: 15°
GP2D150A
REALIABILITY
The reliability of requirements of this device are
listed in Table 1.
Table 1. Reliability
TEST ITEMS
TEST CONDITIONS
Temperature Cycling
One cycle -40°C (30 min.) to +70°C in 30 minutes, re-
peated 25 times
High Temperature and
High Humidity Storage
+40°C, 90% RH, 500h
High Temperature Storage +70°C, 500h
Low Temperature Storage -40°C, 500h
Operational Life
(High Temperature)
+60°C, VCC = 5 V, 500h
Mechanical Shock
100 m / s2, 6.0 ms
3 times / ±X, ±Y, ±Z direction
10-to-55-to-10 Hz i n 1 minute
Variable Frequency Vibration Amplitude: 1.5 mm
2 h i n e a c h X, Y, Z direction
FAILURE
JUDGEMENT
CRITERIA
Initial × 0.8 > VO
VO > Initial × 1.2
SAMPLES (n),
DEFECTIVE (C)
n = 11, C = 0
n = 11, C = 0
n = 11, C = 0
n = 11, C = 0
n = 11, C = 0
n = 6, C = 0
n = 6, C = 0
NOTES:
1. Test conditions are according to Electro-optical Characteristics, shown on page 2.
2. At completion of the test, allow device to remain at nominal room temperature and humidity (non-condensing) for two hours.
3. Confidence level: 90%, Lot Tolerance Percent Defect (LTPD): 20% / 40%.
INCOMING INSPECTION
Inspection Lot
Inspection shall be carried out per each delivery lot.
Inspection Method
A single sampling plan, normal inspection level II
based on ISO 2859 shall be adopted.
Table 2. Quality Level
DEFECT
INSPECTION ITEM/TEST METHOD
AQL (%)
Major Defect Electro-optical characteristics defect
0.4
Minor Defect
Defect to appearance or dimensions (crack, split, chip, scratch,
stain)*
1.0
NOTE: Any one of these that affects the Electro-optical Characteristics shall be considered a defect.
3
Data Sheet