English
Language : 

GP2D150AJ00F Datasheet, PDF (2/9 Pages) Sharp Electrionic Components – Factory set trigger point: 15°
GP2D150A
ELECTRICAL SPECIFICATIONS
Absolute Maximum Ratings
Ta = 25°C, VCC = 5 VDC
PARAMETER
SYMBOL
RATING
UNIT
Supply Voltage
Output Terminal Voltage
Operating Temperature
Storage Temperature
VCC
VO
Topr
Tstg
-0.3 to +7.0
V
-0.3 to (VCC + 0.3) V
-10 to +60
°C
-40 to +70
°C
REMARKS
Open collector output
Operating Supply Voltage
PARAMETER
SYMBOL RATING UNIT
Operating Supply Voltage VCC 4.5 to 5.5 V
Electro-optical Characteristics
Ta = 25°C, VCC = 5 VDC
PARAMETER
SYMBOL
CONDITIONS
MIN. TYP. MAX. UNIT NOTES
Measuring Distance Range
Output Terminal Voltage
Output Distance
Characteristics
Average Supply Current
ΔL
3
— 30 cm 1, 3
VOH Output voltage at high level VCC -0.3 — —
V
1
VOL Output voltage at low level
—
— 0.6 V
1
VO
12.5 15 17.5 cm 1, 2, 4
ICC
—
33 50 mA
NOTES:
1. Measurements made with Kodak R-27 Gray Card, using the white side, (90% reflectivity).
2. Each device is factory set for output switching at L = 15 cm ±2.5 cm.
3. Distance measuring range of the sensor optics.
4. Output switching has hysteresis. The distance specified by VO is the distance at which the output switches from LOW to HIGH.
5. L = Distance to reflective object.
VCC
(POWER SUPPLY)
38.3 ms ±9.6 ms
DISTANCE MEASURMENT
OPERATING
VO
(OUTPUT)
1st
2nd
nth
MEASUREMENT MEASUREMENT MEASUREMENT
UNSTABLE
OUTPUT
1st
OUTPUT
7.6 ms ±1.9 ms
2nd
OUTPUT
Figure 3. Timing Diagram
nth
OUTPUT
GP2D150A-3
2
Data Sheet