English
Language : 

GP1U26R Datasheet, PDF (1/5 Pages) Sharp Electrionic Components – Anti Electromagnetic Induction Noise Type Compact IR Detecting Unit for Remote Control
GP1U26R/27R/28R/28Q Series
GP1U26R/GP1U27R Series
GP1U28R/GP1U28Q Series
Anti Electromagnetic Induction
Noise Type Compact IR Detecting
Unit for Remote Control
s Features
1. Anti electromagnetic induction noise type
2. Compact (case volume)
(GP1U28Q : About 1/4 compared with GP1U78Q)
3. Power filter capacitor and resistance are not required any more
as a result of adoption of built-in constant voltage circuit
4. Various B.P.F. (Band Pass Frequency) frequency to meet different user needs
s Applications
1. AV equipment such as TV sets,
VCRs and audio equipment
2. HA equipment such as air conditioners
and electric fans
s Outline Dimensions
GP1U26R Series
7.3
0.5
2 5.2 3.6
GP1U27R Series
7.3
0.5
(Unit : mm)
2
10.4
3.6
Φ 4.5
Marking
Φ 4.5
Marking
*1
2.54
*1
2.54
4
Recommended drilling as viewed from the soldering face.
3.75 3.75
1.2
*1
2.54
*1
2.54
4
Recommended drilling as viewed from the soldering face.
3.75 3.75
1.2
2-0.5
2-0.4
2-0.75
0.6 1 2 3 0.6
2-0.75
1 Vout
2 VCC
3 GND
1.2
Detector
center
(0.5)
Φ 0.8
2.54
2.54
1. Unspecified tolerance : ± 0.3
GP1U28R Series
7.3
0.5
2
2. * 1 : The dimension of lead base
14.4
3.6
2-0.5
2-0.4
2-0.75
1
0.6
23
2-0.75
1 Vout
2 VCC
3 GND
0.6
1.2
Detector
center
(0.5)
Φ 0.8
2.54
2.54
1. Unspecified tolerance : ± 0.3
GP1U28Q Series
7.3
0.5
2. * 1 : The dimension of lead base
24
Φ 4.5
Marking
Marking
*1
2.54
*1
2.54
4
Recommended drilling as viewed from the soldering face.
3.75 3.75
1.2
1.2
2-0.5
2-0.4
2-0.75
1 Vout
2 VCC
3 GND
0.6 1 2 3 0.6
2-0.75
Detector
center
(0.5)
Φ 0.8
2.54
2.54
1. Unspecified tolerance : ± 0.3 2. * 1 : The dimension of lead base
0.4
0.6 1 2 3 0.6
1.6
3.7
1.4
1.4
5.4
6.8
1 Vout
2 VCC Recommended drilling as viewed from the soldering face.
3 GND
2.54
2.54
0.8
Φ
0.5
*1
2.54
*1
2.54
1. Unspecified tolerance : ± 0.3
1.2
1.2
3.75 3.75
2. * 1 : The dimension of lead base
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”