English
Language : 

6N135 Datasheet, PDF (1/5 Pages) Toshiba Semiconductor – IRED & PHOTO IC (DIGITAL LOGIC ISOLATION)
6N135/6N136
6N135/6N136
General Purpose Type
Photocoupler
s Features
1. High speed response t PHL , t PLH
(6N135 : MAX. 1.5 µ s at R L = 4.1k Ω )
(6N136 : MAX. 0.8 µ s at R L = 1.9k Ω )
2. High common mode rejection voltage
( CM H : TYP. 1kV/ µ s )
3. Standard dual-in-line package
4. Recognized by UL, file No. E64380
s Applications
1. Computers, measuring instruments, control
equipment
2. High speed line receivers, high speed logic
3. Telephone sets
4. Signal transmission between circuits of
different potentials and impedances
s Outline Dimensions
( Unit : mm)
0.85 ± 0.3
8 76
Model
1.2 ± 0.3 No.
5
Internal
connection
diagram
8 7 65
6N
1
2 34
0.8
Primary side mark
(Sunken place )
9.22 ± 0.5
1 2 34
7.62 ± 0.3
0.5 ± 0.1
2.54 ± 0.25
θ = 0 to 13˚
0.26 ± 0.1
θ
1 NC
5 GND
s Absolute Maximum Ratings ( Ta = 25˚C)
Parameter
Symbol Rating
Input
Forward current
*1Peak forward current
*2Peak transient
forward current
Reverse voltage
IF
25
IF
50
I FM
1
VR
5
Power dissipation
P
45
Supply voltage
V CC - 0.5 to + 15
Output
Output voltage
Emitter-base reverse with-
stand voltage ( Pin 5 to 7 )
Average output current
VO
V EBO
IO
- 0.5 to + 15
5
8
Peak output current
I OP
16
Base current ( Pin 7 ) IB
5
Power dissipation
*3Isolation voltage
PO
100
V iso 2 500
Operating temperature
T opr - 55 to + 100
Storage temperature
*4Soldering temperature
T stg - 55 to + 125
T so1
260
Unit
mA
mA
A
V
mW
V
V
V
mA
mA
mA
mW
V rms
˚C
˚C
˚C
2 Anode
3 Cathode
4 NC
6 VO
7 VB
8 V CC
* “ OPIC ” ( Optical IC ) is a trademark of the SHARP Corporation.
An OPIC consists of a light-detecting element and signal-
processing circuit integrated onto a single chip.
*1 50% duty cycle, Pulse width : 1ms
Decreases at the rate of 1.6mA/˚C if the external temperature is 70˚C or more.
*2 Pulse width<=1µ s, 300 P/ S
*3 40 to 60% RH, AC for 1 minute
*4 For 10 seconds
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.”