English
Language : 

SC622A_09 Datasheet, PDF (6/23 Pages) Semtech Corporation – LED Light Management Unit Charge Pump, 400mA Flash LED,Dual LDOs,and I2C Interface
SC622A
Electrical Characteristics (continued)
Parameter
I2C Interface (continued)
I/O Pin Capacitance
I2C Timing
Clock Frequency
SCL Low Period(4)
SCL High Period(4)
Data Hold Time(4)
Data Setup Time(4)
Setup Time for Repeated
START Condition(4)
Hold Time for Repeated
START Condition(4)
Setup Time for STOP
Condition(4)
Bus-Free Time Between
STOP and START(4)
Symbol
C
IN
f
SCL
t
LOW
t
HIGH
t
HD_DAT
t
SU_DAT
t
SU_STA
t
HD_STA
t
SU_STO
t
BUF
Conditions
Min Typ Max Units
10
pF
400 440 kHz
1.3
μs
0.6
μs
0
μs
100
μs
0.6
μs
0.6
μs
0.6
μs
1.3
μs
Interface Start-up Time(4)
t
Bus Start-up Time After EN Pin is Pulled High
EN
1
ms
Notes:
(1) Once tripped, flash output will remain disabled until FLEN pin is cycled or reset via serial interface.
(2) Test voltage is V = 4.5V — a relatively extreme LED voltage — to force a transition during test. Typically V = 3.3V for the white LED at
OUT
OUT
100mA.
(3) Dropout is defined as (V -V ) whenV drops 100mV from nominal. Dropout does not apply to LDO2 since it has a maximum output voltage
IN LDO1
LDO1
of 1.8V.
(4) Guaranteed by design
6