English
Language : 

LV0229XA Datasheet, PDF (5/8 Pages) Sanyo Semicon Device – Front Monitor OE-IC
LV0229XA
Resister table
Enable selection of the register group from the SSEL pin.
SSEL = Low
Address
7
6
5
4
3
2
1
0
Name
POWER
IV GAIN SEL
Default
00h
Value
00
11: Power on
00/01/10: Sleep
00
00/01: High
10: Middle
0
0
0
0
11: Low
Name
GAIN
Default
01h
1
1
1
1
1
1
1
1
Value
00000000 to 11111111
Name
0Eh
TEST1 (*1)
SSEL = High
Address
7
6
5
4
3
2
1
0
Name
POWER
IV GAIN SEL
Default
10h
Value
00
11: Power on
00/01/10: Sleep
00
00/01: High
10: Middle
11: Low
0
0
0
0
Name
GAIN
Default
11h
1
1
1
1
1
1
1
1
Value
00000000 to 11111111
Name
1Eh
TEST1 (*1)
SSEL = Open
Address
7
6
5
4
3
2
1
0
Name
POWER
IV GAIN SEL
Default
70h
Value
00
11: Power on
00/01/10: Sleep
00
00/01: High
10: Middle
0
0
0
0
11: Low
Name
GAIN
Default
71h
1
1
1
1
1
1
1
1
Value
00000000 to 11111111
Name
7Eh
TEST1 (*1)
*1 TEST1 are either the time when power is applied or “00000000” is set. Do not attempt to change “00000000” during operation.
“00000000” is returned when reading is made.
*2 No problem in terms of operation occurs even when writing is made to the address 02h to 0Dh & 0Fh, 12h to 1Dh & 1Fh and 72h to 7Dh & 7Fh.
“00000000” is returned when this address is read.
*3 When I performed address reading except the register group set by an SSEL terminal, I keep Hi-Z without paying a value.
No.A2144-5/8