English
Language : 

DU16H711S Datasheet, PDF (45/68 Pages) Sanyo Semicon Device – 2-PHASE STEPPING SYSTEMS
˙ Pulse rate-torque characteristics
˙ SH2861-04 ˘˘
280 20 2.0
240 16 1.6
200
12 1.2
160
Pull-out torque at JL1
120 8 0.8
80
4 0.4
40
00 0
0.1
fs
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 4A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ7.4x10-4kgɾm2ʢ40.46 ozɾin2ʣuse the rubber couplingʧ
˙ SH2862-04 ˘˘
700 50 5.0
600 40 4.0
500
30 3.0
400
300 20 2.0
Pull-out torque at JL1
200
10 1.0
100
00 0
0.1
fs
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 2A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ15.3x10-4kgɾm2ʢ83.65 ozɾin2ʣuse the rubber couplingʧ
˙ SH2863-04 ˘˘
700 50 5.0
600 40 4.0
500
30 3.0
400
Pull-out torque at JL1
300 20 2.0
200
10 1.0
100
00 0
0.1
fs
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 4A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ15.3x10-4kgɾm2ʢ83.65 ozɾin2ʣuse the rubber couplingʧ
˙ SM2861-50 ˘˘ɹɹ
560 40 4.0
480 32 3.2
400
24 2.4
320
Pull-out torque at JL1
240 16 1.6
160
8 0.8
80
Starting torque
at JL2
00 0
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 2A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ7.4x10-4kgɾm2ʢ40.46 ozɾin2ʣuse the rubber couplingʧ
˙ SM2861-51 ˘˘
560 40 4.0
480 32 3.2
400
24 2.4
320
Pull-out torque at JL1
240 16 1.6
160
8 0.8
80
00 0
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 4A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ7.4x10-4kgɾm2ʢ40.46 ozɾin2ʣuse the rubber couplingʧ
˙ SM2861-52 ˘˘
560 40 4.0
480 32 3.2
400
24 2.4
320
Pull-out torque at JL1
240 16 1.6
160
8 0.8
80
00 0
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 6A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ15.3x10-4kgɾm2ʢ83.65 ozɾin2ʣuse the rubber couplingʧ
˙ SM2862-50 ˘˘
1400 100 10
1200 80 8
1000
60 6
800
600 40 4
Pull-out torque at JL1
400
20 2
200
0 00
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 2A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ15.3x10-4kgɾm2ʢ83.65 ozɾin2ʣuse the rubber couplingʧ
˙ SM2862-51 ˘˘
1400 100 10
1200 80 8
1000
60 6
800
600 40 4
Pull-out torque at JL1
400
20 2
200
0 00
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 4A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ15.3x10-4kgɾm2ʢ83.65 ozɾin2ʣuse the rubber couplingʧ
˙ SM2862-52 ˘˘
1400 100 10
1200 80 8
1000
60 6
800
Pull-out torque at JL1
600 40 4
400
20 2
200
0 00
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 6A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ15.3x10-4kgɾm2ʢ83.65 ozɾin2ʣuse the rubber couplingʧ
˙ SM2863-50 ˘˘
1400 100 10
˙ SM2863-51 ˘˘
1400 100 10
˙ SM2863-52 ˘˘
1400 100 10
1200 80 8
1000
60 6
800
Pull-out torque at JL1
1200 80 8
1000
60 6
800
Pull-out torque at JL1
1200 80 8
1000
60 6
800
Pull-out torque at JL1
600 40 4
600 40 4
600 40 4
400
20 2
200
400
20 2
200
400
20 2
200
0 00
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
0 00
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
0 00
0.1
1
10
Pulse rateʢkpulse/sʣ
100
1000 2000 3000 5000
Number of rotationsʢmin-1ʣ
100
Constant current circuit
Source voltage : DC100Vɾoperating current : 2A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ43x10-4kgɾm2ʢ235.10 ozɾin2ʣuse the rubber couplingʧ
Constant current circuit
Source voltage : DC100Vɾoperating current : 4A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ43x10-4kgɾm2ʢ235.10 ozɾin2ʣuse the rubber couplingʧ
Constant current circuit
Source voltage : DC100Vɾoperating current : 6A/phase,
2-phase energizationʢfull-stepʣ
JL1 =ʦ43x10-4kgɾm2ʢ235.10 ozɾin2ʣuse the rubber couplingʧ
44 The date are measured under the drive condition of our company. The drive torque may very depending on the accuracy of customer-side equipment.