LA9230M Datasheet, PDF (11/20 Pages) Sanyo Semicon Device – Analog Signal Processor ASP for CD players
LA9230M/9231M
Microprocessor Command List
MSB LSB Command
0 0 0 0 0 0 0 0 RESET
0 0 0 0 1 0 0 0 FOCUS START
1 1 1 1 0 0 0 0 2BYTE-COMMAND DETECT
1 1 1 1 1 0 0 0 2BYTE-COMMAND DETECT
1 1 1 1 1 1 1 1 2BYTE-COMMAND RESET
1 0 0 1 0 0 0 0 FOCUS-OFFSET ADJUST START
1 0 0 1 0 0 0 1 FOCUS-OFFSET ADJUST OFF
1 0 0 1 0 0 1 0 TRACK-OFFSET ADJUST START
1 0 0 1 0 0 1 1 TRACK-OFFSET ADJUST OFF
1 0 0 1 0 1 0 0 LASER ON
1 0 0 1 0 1 0 1 LASER OFF : F-SERVO ON
1 0 0 1 0 1 1 0 LASER OFF : F-SERVO OFF
1 0 0 1 0 1 1 1 SPINDLE 8CM
1 0 0 1 1 0 0 0 SPINDLE 12 CM
1 0 0 1 1 0 0 1 SPINDLE OFF
1 0 0 1 1 0 1 0 SLED ON
1 0 0 1 1 0 1 1 SLED OFF
1 0 0 1 1 1 0 0 E/F BALANCE START
1 0 0 1 1 1 0 1 TRACK-SERVO OFF
1 0 0 1 1 1 1 0 TRACK-SERVO ON
Reset mode
Power on mode
V
V
V
V
V
Nonadjusted
V
DSP
RESET(NOTHING)
FOCUS START #1
2BYTE-COMMAND DETECT
2BYTE-COMMAND DETECT
2BYTE-COMMAND RESET
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Notes Concerning Microprocessor Program Creation
1. Commands
After sending the FOCUS START command and the E/F BALANCE START command, send 11111110 (FEH) in order to
clear the internal registers of the IC.
Reason: Although the above commands are executed at point 1 in the timing chart below, the same commands will be
executed again at point 2 if there is subsequent input to CE as shown below.
Timing
2 µs or more
2 µs or more
10 µs or more
1 µs or more
1 µs or more
‘‘FOCUS START’’ command
‘‘E/F BALANCE START’’ command
When sending a TRACK-OFFSET ADJUST START command or a FOCUS-OFFSET ADJUST START command after either
VCC ON (POWER ON RESET), RESET command, or a corresponding OFFSET ADJUST OFF command, waiting time is
necessary as listed below. (Only when a 4.2 MHz clock is input.)
TRACK-OFFSET ADJUST START: 4 ms or more
FOCUS-OFFSET ADJUST START: 30 ms or more
2. E/F balance adjustment
E/F balance adjustments should be made in a bit region of the disc, not a mirrored region. (This is because the E/F balance
adjustment entails about 100 to 200 track kicks.)
Since there is no track-kick for LA9231M, measures must be taken during EF balance adjustment to obtain a stable TE
signal. (By a sled movement signal from a microprocessor, for example.)
No.5189 - 11/20