English
Language : 

LS33600C Datasheet, PDF (1/2 Pages) saftbatteries – 3.6 V Primary lithium-thionyl chloride High energy D-size bobbin cell
Primary lithium battery
LS 33600C
3.6 V Primary lithium-thionyl chloride (Li-SOCI2)
High energy
D-size bobbin cell
(recommended for cool temperature environments)
Benefits
q High voltage response, stable during
most of the lifetime of the application
q Superior voltage response during
pulsing at ambient T
q Easy integration in compact system
q Low self-discharge rate
(less than 3% after 1 year of storage
at +20°C)
Cell size references
UM3 - R20 - D
Electrical characteristics
(typical values relative to cells stored for one year or less at + 30°C max.)
Nominal capacity
(at 1 mA + 20 °C 2.0 V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off)
Open circuit voltage (at + 20°C)
Nominal voltage
(at 0.7 mA + 20°C)
18.5 Ah
3.67 V
3.6 V
Key features
q Stainless steel container
q Hermetic glass-to-metal sealing
q Built-in safety vent
q Finish with or without flat positive end
q Non-flammable electrolyte
q Compliant with IEC 86-4
safety standard and EN 50020
intrinsic safety standard
q Underwriters Laboratories (UL)
Component Recognition
(File Number MH 12609)
q Restricted for transport (Class 9)
Pulse capability: Typically up to 250 mA.
(250 mA/0.1 second pulses, drained every 2 mn at + 20°C from
undischarged cells with 10 µA base current, yield voltage readings above
3.0 V. The readings may vary according to the pulse characteristics, the
temperature, and the cell's previous history. Fitting the cell with a capacitor
may be recommended in severe conditions. Consult Saft)
Continuous current permitting 50% of the nominal capacity
to be achieved at + 20°C with 2.0 V cut off.
(to maintain cell heating within safe limits. Battery packs may imply lower
level of maximum current and may request specific thermal protection.
Consult Saft)
80 mA
Storage
(recommended)
(for more severe conditions, consult Saft)
+ 30°C (+ 86°F) max
Operating temperature range
(Operation above ambient T may lead to reduced capacity and
lower voltage plateau readings at the beginning of pulses. Consult Saft)
- 60°C/+ 70°C
(- 76°F/+ 158°F)
Main applications
q Utility metering
q Automatic meter readers
q Buoys
q Measuring equipment
q Industrial applications
q Professional electronics
Optional upon request
q Low magnetic version
Physical characteristics
Diameter (max)
Height (max)
Typical weight
Li metal content
Available termination suffix
CN, CNR
CNA (AX)
FL
33.4 mm (1.32 in)
60.2 or 61.6 mm
(2.37 or 2.42 in)
depending on finish type
90 g (3.2 oz)
approx. 4.9 g
radial tabs
axial leads
flying leads ... etc.
November 2006