English
Language : 

BU97930MUV_15 Datasheet, PDF (9/32 Pages) Rohm – Multifunction LCD Segment Driver
BU97930MUV MAX 108 segments (SEG27×COM4)
○Blink function
This device has Blink function. Blink function can set each segment port individually.
Blink ON/OFF and Blink frequency are set by the BLKSET command.
Blink frequency varies according to fCLK characteristics.
Blink setup of each segment is controlled by BLKWR command.
The write start address is specified by “BLKADSET” command. And this address will automatically increment every 4 bits
of blink data received. The relation of BLKWR command, blink ram data, and blinking segment port is below.
In case data is “1”, segment will blink, on the other hand when data is “0”, segment will not blink.
(In case data is written continuously after write data at 1Ah (SEG26), RAM data will be written to 1Bh (dummy address)
and return to address 00h (SEG0) automatically.)
Please refer to the following figures about Blink operation of each segment.
In case SEG port assigned to GPO port by OUTSET command, corresponding SEG address does not change and used
as dummy address.
1st Byte 2nd Byte 1st Byte 2nd Byte
Command Command Command Command Command
10000100 00000011 10000111 00000000 11000000 a b c d e f g h i j k l m n o p …
Blink set
Blink Address set
Blink
RAMWR
Blink RAM data
Blink RAM address
00
01
02
03
04
05
06
07 ・・・ 19h 1Ah 1Bh
0a
e
i
m
COM0
1b
f
j
n
COM1
BIT 2 c
3d
SEG
0
g
h
SEG
1
k
l
SEG
2
o
p
SEG
3
SEG
4
SEG
5
SEG
6
SEG
7
SEG SEG
25 26
COM2
COM3
DDRAM data
SEG A
SEG B
SEG C
SEG D
Blink RAM data
SEG A
SEG B
SEG C
SEG D
Segment output
SEG A
SEG B
SEG C
SEG D
SEG A
SEG B
SEG C
SEG D
SEG A
SEG B
SEG C
SEG D
Blink frequency
under the 2Hz stting segment output will blink every 0.5 second (ON->OFF->ON)
SEG A
SEG B
SEG C
SEGA/B is blink
SEG D
Figure 9. Blink Operation
www.rohm.com
© 2013 ROHM Co., Ltd. All rights reserved.
TSZ22111ï½¥15ï½¥001
9/28
TSZ02201-0A0A2D300060-1-2
10.Apr.2015 Rev.004