BU21072MUV_16 Datasheet, PDF (31/40 Pages) Rohm – Capacitive Switch Controller ICs
BU21072MUV / BU21078MUV / BU21078FV
(10) Ground wiring pattern
If small-signal GND and large-current GND are provided, It will be recommended to separate the large-current
GND pattern from the small-signal GND pattern and establish a single ground at the reference point of the set
PCB so that resistance to the wiring pattern and voltage fluctuations due to a large current will cause no
fluctuations in voltages of the small-signal GND. Pay attention not to cause fluctuations in the GND wiring pattern
of external parts as well.
(11) External capacitor
In order to use a ceramic capacitor as the external capacitor, determine the constant with consideration given to a
degradation in the nominal capacitance due to DC bias and changes in the capacitance due to temperature, etc.
(12) Rush current
The IC with some power supplies has a capable of rush current due to procedure and delay at power-on. Pay
attention to the capacitance of the coupling capacitors and the wiring pattern width and routing of the power
supply and the GND lines.