BU52002GUL,BU52003GUL,BU52012HFV,BU52013HFV
Technical Note
BU52012HFV (Unless otherwise specified, VDD=1.80V, Ta=25℃)
Parameters
Symbol Min
Limit
Typ
Max
Unit
Power Supply Voltage
VDD
1.65
1.80
3.30
V
Conditions
Operate Point
BopS
-
3.0
5.0
mT
Release Point
BrpS
0.6
2.1
-
mT
Hysteresis
BhysS
-
0.9
-
mT
Period
TP
-
50
100
ms
Output High Voltage
VOH
VDD-0.2
-
-
V B<BrpS※6 , IOUT =-0.5mA
Output Low Voltage
VOL
-
-
0.2
V BopS<B※6 , IOUT =+0.5mA
Supply Current 1
IDD1(AVG)
-
3.5
5.5
μA VDD=1.8V, Average
Supply Current During Startup Time 1
IDD1(EN)
-
2.8
-
mA
VDD=1.8V,
During Startup Time Value
Supply CurrentDuring Standby Time 1
IDD1(DIS)
-
1.8
-
μA
VDD=1.8V,
During Standby Time Value
Supply Current 2
IDD2(AVG)
-
6.5
9
μA VDD=2.7V, Average
Supply Current During Startup Time 2
IDD2(EN)
-
4.5
-
mA
VDD=2.7V,
During Startup Time Value
Supply CurrentDuring Standby Time 2
IDD2(DIS)
-
4.0
-
μA
VDD=2.7V,
During Standby Time Value
※6. B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output. Radiation hardiness is not designed.
BU52013HFV (Unless otherwise specified, VDD=1.80V, Ta=25℃)
Parameters
Symbol Min
Limit
Typ
Max
Unit
Power Supply Voltage
VDD
1.65
1.80
3.30
V
Conditions
Operate Point
BopN
-5.0
-3.0
-
mT
Release Point
BrpN
-
-2.1
-0.6
mT
Hysteresis
BhysN
-
0.9
-
mT
Period
Output High Voltage
Output Low Voltage
TP
-
50
VOH
VDD-0.2
-
VOL
-
-
100
ms
-
V
BrpN<B※7 , IOUT =-0.5mA
0.2
V
B<BopN※7 , IOUT =+0.5mA
Supply Current 1
IDD1(AVG)
-
3.5
5.5
μA VDD=1.8V, Average
Supply Current During Startup Time 1
IDD1(EN)
-
2.8
-
mA
VDD=1.8V,
During Startup Time Value
Supply CurrentDuring Standby Time 1
IDD1(DIS)
-
1.8
-
μA
VDD=1.8V,
During Standby Time Value
Supply Current 2
IDD2(AVG)
-
6.5
9
μA VDD=2.7V,Average
Supply Current During Startup Time 2
IDD2(EN)
-
4.5
-
mA
VDD=2.7V,
During Startup Time Value
Supply CurrentDuring Standby Time 2
IDD2(DIS)
-
4.0
-
μA
VDD=2.7V,
During Standby Time Value
※7 B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output. Radiation hardiness is not designed.
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
3/13
2010.01 - Rev.B