English
Language : 

BU97981KV-E2 Datasheet, PDF (24/50 Pages) Rohm – Multi-function LCD Segment Drivers
BU97981xxx Series MAX 196 segments (SEG49xCOM4)
Datasheet
SEG/GPO Port Change (OUTSET1)
MSB
LSB
D/C D6 D5 D4 D3 D2 D1 D0 Hex Reset
1st byte Command
1
0
0
0
1
0
0
0 88h
-
2nd byte Command
0
0
0 P4 P3 P2 P1 P0
-
00h
Set output mode, Segment output or GPO output.
P4 to P0: Select changing port number. (SEG15 to SEG45 ports are SEG mode/GPO mode selectable)
In case, GPO output is selected, Terminal output data is set by GPOSET command.
Ex) In case SEG45 port assigned to GPO,
If GPO1 data is “H”, GPO1 (SEG45) port outputs “H” (VLCD Level).
If GPO1 data is “L”, GPO1 (SEG45) port outputs “L” (VSS level).
Output terminal state under the P2 to P0 set condition is listed below
(BU97981KV ,BU97981GU)
Condition
SEG Terminal state (SEG output/GPO output)
P4 P3 P2
P1 P0
SEG15
Terminal
SEG16
Terminal
SEG17
Terminal
SEG18
Terminal
SEG42 SEG43 SEG44 SEG45
Terminal Terminal Terminal Terminal
0 0 0 0 0 SEG15 SEG16 SEG17 SEG18
SEG42 SEG43 SEG44 SEG45
0 0 0 0 1 SEG15 SEG16 SEG17 SEG18
SEG42 SEG43 SEG44 GPO1
0 0 0 1 0 SEG15 SEG16 SEG17 SEG18
SEG42 SEG43 GPO2 GPO1
0 0 0 1 1 SEG15 SEG16 SEG17 SEG18
SEG42 GPO3 GPO2 GPO1
0 0 1 0 0 SEG15 SEG16 SEG17 SEG18
GPO4 GPO3 GPO2 GPO1
・
・
・
・
・
・
1 1 0 1 1 SEG15 SEG16 SEG17 SEG18
GPO4 GPO3 GPO2 GPO1
1 1 1 0 0 SEG15 SEG16 SEG17 GPO28
GPO4 GPO3 GPO2 GPO1
1 1 1 0 1 SEG15 SEG16 GPO29 GPO28
GPO4 GPO3 GPO2 GPO1
1 1 1 1 0 SEG15 GPO30 GPO29 GPO28
GPO4 GPO3 GPO2 GPO1
1 1 1 1 1 GPO31 GPO30 GPO29 GPO28
GPO4 GPO3 GPO2 GPO1
(BU97981MUV)
Condition
SEG Terminal state (SEG output/GPO output)
P4 P3 P2
P1 P0
SEG12
Terminal
SEG13
Terminal
SEG14
Terminal
SEG15
Terminal
SEG35 SEG36 SEG37 SEG38
Terminal Terminal Terminal Terminal
0 0 0 0 0 SEG12 SEG13 SEG14 SEG15
SEG35 SEG36 SEG37 SEG38
0 0 0 0 1 SEG12 SEG13 SEG14 SEG15
SEG35 SEG36 SEG37 GPO1
0 0 0 1 0 SEG12 SEG13 SEG14 SEG15
SEG35 SEG36 GPO2 GPO1
0 0 0 1 1 SEG12 SEG13 SEG14 SEG15
SEG35 GPO3 GPO2 GPO1
0 0 1 0 0 SEG12 SEG13 SEG14 SEG15
GPO4 GPO3 GPO2 GPO1
・
・
・
・
・
・
1 0 1 1 1 SEG12 SEG13 SEG14 SEG15
GPO4 GPO3 GPO2 GPO1
1 1 0 0 0 SEG12 SEG13 SEG14 GPO24
GPO4 GPO3 GPO2 GPO1
1 1 0 0 1 SEG12 SEG13 GPO25 GPO24
GPO4 GPO3 GPO2 GPO1
1 1 0 1 0 SEG12 GPO26 GPO25 GPO24
GPO4 GPO3 GPO2 GPO1
1 1 0 1 1 GPO27 GPO26 GPO25 GPO24
GPO4 GPO3 GPO2 GPO1
11100 – 11111
GPO27 GPO26 GPO25 GPO24
GPO4 GPO3 GPO2 GPO1
In case, the SEG port is switched to the GPO port, DDRAM address and Blink RAM address do not change.
In this case, DDRAM address and Blink RAM address, selected GPO output mode, is dummy address.
www.rohm.com
© 2012 ROHM Co., Ltd. All rights reserved.
TSZ22111ï½¥15ï½¥001
24/46
TSZ02201-0A2A0D300110-1-2