English
Language : 

BU52058GWZ Datasheet, PDF (2/18 Pages) Rohm – Omnipolar Detection Hall IC
BU52058GWZ
●Absolute Maximum Ratings (Ta=25℃)
Parameter
Symbol
Ratings
Power Supply Voltage VDD
-0.1 to +4.5*1
Output Current
IOUT
±0.5
Power Dissipation
Pd
100
Operating
Temperature Range
Topr
Storage
Temperature Range
Tstg
*1. Not to exceed Pd
-40 to +85
-40 to +125
Datasheet
Unit
V
mA
mW
℃
Remarks
Reduced by 1.00mW for each increase in Ta of 1℃ over 25
(mounted on 24mm×20mm Glass-epoxy PCB)
℃
●Magnetic, Electrical characteristics
BU52058GWZ (Unless otherwise specified, VDD=1.80V, Ta=25℃)
PARAMETERS
SYMBOL
LIMIT
MIN TYP MAX
Power Supply Voltage
VDD
1.65 1.80 3.60
Operate Point
BopS
BopN
-
3.0 5.0
-5.0 -3.0 -
Release Point
BrpS
0.6 2.1
-
BrpN
- -2.1 -0.6
Hysteresis
BhysS
BhysN
-
0.9
-
-
0.9
-
Period
Output High Voltage
Output Low Voltage
Tp
-
50 100
VOH
VDD
-0.2
-
-
VOL
-
-
0.2
Supply Current
IDD(AVG)
-
5
8
Supply Current During Startup Time
IDD(EN)
-
2.8
-
Supply Current During Standby Time
IDD(DIS)
-
1.8
-
※2. B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to
the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
UNIT
V
mT
mT
mT
ms
V
V
μA
mA
μA
CONDITIONS
OUTPUT:OUT1
(respond the south pole)
OUTPUT:OUT2
(respond the north pole)
OUTPUT:OUT1
(respond the south pole)
OUTPUT:OUT2
(respond the north pole)
BrpN<B<BrpS
※2
IOUT =-0.5mA
B<BopN, BopS<B
※2
IOUT =+0.5mA
Average
During Startup Time Value
During Standby Time Value
www.rohm.com
© 2013 ROHM Co., Ltd. All rights reserved.
TSZ22111・15・001
2/14
TSZ02201-0M3M0F413010-1-2
14.Feb.2013 Rev.001