English
Language : 

BU52040HFV_10 Datasheet, PDF (2/13 Pages) Rohm – Bipolar Latch Hall IC
BU52040HFV
Technical Note
●Magnetic, Electrical Characteristics
BU52040HFV (Unless otherwise specified, VDD=1.80V, Ta=25°C)
Parameters
Limit
Symbol
Unit
Min
Typ
Max
Power Supply Voltage
VDD
1.65
1.80
3.30
V
Conditions
Operation point
Bop
1.0
3.0
5.0
mT
Release Point
Brp
-5.0
-3.0
-1.0
mT
Hysteresis
Bhys
-
6.0
-
mT
Period
Output High Voltage
Output Low Voltage
Tp
-
500
VOH
VDD - 0.2
-
VOL
-
-
1200
-
0.2
µs
V
B < Brp※3
IOUT =-0.5mA
V
Bop < B※3
IOUT =+0.5mA
Supply Current 1
IDD1(AVG)
-
200
300
µA
VDD =1.8V, Average
Supply Current
During Startup Time 1
IDD1(EN)
-
3.0
-
mA
VDD =1.8V,
During Startup Time Value
Supply Current
During Standby Time 1
IDD1(DIS)
-
2.0
-
µA
VDD =1.8V,
During Standby Time Value
Supply Current 2
IDD2(AVG)
-
300
450
µA
VDD=2.7V, Average
Supply Current
During Startup Time 2
IDD2(EN)
-
4.5
-
mA
VDD=2.7V,
During Startup Time Value
Supply Current
During Standby Time 2
IDD2(DIS)
-
3.5
-
µA
VDD=2.7V,
During Standby Time Value
※3. B = Magnetic flux density
1mT=10Gauss
Positive (“+”) polarity flux is defined as the magnetic flux from south pole which is direct toward to the branded face of the sensor.
After applying power supply, it takes one cycle of period (TP) to become definite output.
Radiation hardiness is not designed.
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
2/12
2010.01 - Rev.B