(2) Under Voltage Lockout Protection (UVLO)
The Under Voltage Lockout Protection circuit monitors the AVIN terminal voltage.
The operation enters standby when the AVIN terminal voltage is 2.45V (Typ) or lower.
The operation starts when the AVIN terminal voltage is 2.55V (Typ) or higher.
VIN
UVLO OFF
hys
UVLO ON
0V
Datasheet
VOUT
FB
terminal
High side
MOSFET gate
Soft start
Low side
MOSFET gate
Normal operation
UVLO
Normal operation
Figure 47. UVLO Timing Chart
(3) Thermal Shutdown
When the chip temperature exceeds Tj=175C, the DC/DC converter output is stopped. The thermal shutdown circuit
is intended for shutting down the IC from thermal runaway in an abnormal state with the temperature exceeding
Tjmax=150C. It is not meant to protect or guarantee the soundness of the application. Do not use the function of
this circuit for application protection design.