BD9B300MUV Datasheet, PDF (18/33 Pages) Rohm – Over Current Protection
BD9B300MUV
Datasheet
2. Protection
The protective circuits are intended for prevention of damage caused by unexpected accidents. Do not use them
for continuous protective operation
(1) Over Current Protection (OCP) / Short Circuit Protection (SCP)
Setting of Over current protection is 5.0A (typ.). When OCP is triggered, over current protection is realized by
restricting On / Off Duty of current flowing in upper MOSFET by each switching cycle. Also, if Over current protection
operates 1024 cycles in a condition where FB terminal voltage reaches below 70% of internal standard voltage,
Short Circuit protection (SCP) operates and stops switching for 1msec (typ.) before it initiates restart. However,
during startup, Short circuit protection will not operate even if the IC is still in the SCP condition.
Table 1. Over Current Protection / Short Circuit Protection Function
EN terminal PGD
Startup
Over current
protection
L
More than 2.0V
While start up
Startup completed
Valid
Valid
H
*
Valid
Less than 0.3V *
*
Invalid
Short circuit
protection
Invalid
Valid
Invalid
Invalid
VOUT
1ms(typ.)
FB
High side
MOSFET gate
Low side
MOSFET gate
OCP threshold
Coil current
Inside IC
OCP signal
PGD
1024 Cycle
Figure 46. Short Circuit Protection (SCP) Timing Chart
www.rohm.com
© 2014 ROHM Co., Ltd. All rights reserved.
TSZ22111 • 15 • 001
18/30
TSZ02201-0J2J0AJ00410-1-2
23.May.2014 Rev.001