English
Language : 

BU8710AKS Datasheet, PDF (16/32 Pages) Rohm – 4-channel ADPCM transcoder for digital cordless telephone base stations
Communication ICs
2) Internal register mapping
BU8710AKS
S Command No.: 0 (NOP)
No processing is carried out with this command.
S Command No.: 1 (RESET)
Writing “H” to the corresponding internal register initial-
izes the individual encoder and decoder for the channel.
The status at this point is the optional reset status noted
in the 1988 edition of the CCITT recommendations for
the G.721.
RESE1A G G Channel 1-A encoder initialized
RESE1B G G Channel 1-B encoder initialized
RESE2A G G Channel 2-A encoder initialized
RESE2B G G Channel 2-B encoder initialized
RESD1A G G Channel 1-A decoder initialized
RESD1B G G Channel 1-B decoder initialized
RESD2A G G Channel 2-A decoder initialized
RESD2B G G Channel 2-B decoder initialized
114