English
Language : 

BU9844GUL-W_13 Datasheet, PDF (14/30 Pages) Rohm – WLCSP EEPROM
BU9844GUL-W (16Kbit)
Datasheet
2. Notes on write cycle continuous input
SDA
LINE
S
W
T
R
A
R
T
SLAVE
ADDRESS
I
T
E
WORD
ADDRESS(n)
DATA(n)
S
T
DATA(n+15)
O
P
1 0 1 0 P2P1P0 WA
7
RA
/C
WK
WA
0 D7
A
C
K
D0
A
C
K
D0
A
C
K
Figure 34. Page write cycle
At STOP (stop bit),
Write starts.
S
T
A
R
T
1 0 10
Next command
tWR (maximum : 5ms)
Command is not accepted for this period.
Note)
1 0 1 0 P2 P1 P0
Figure 35. Difference of each type of slave address
3. Notes on page write cycle
List of numbers of page write
Number of Pages
16Byte
Product number
BU9844GUL-W
○Internal address increment
Page write mode
WA7 ----- WA4 WA3
0 ----- 0
0
0 ----- 0
0
0 ----- 0
0
WA2
0
0
0
WA1
0
0
0
WA0
0
0
0
Increment
The above numbers are maximum bytes for respective types.
Any types below these can be written.
0Eh 0 ----- 0
0 ----- 0
1page = 16 bytes, but the page write cycle write time is 5ms at maximum
for 16byte bulk write.
It does not stand 5ms at maximum x 16 bytes = 80ms (Max.).
0 ----- 0
1110
1111
0000
Significant bit is fixed.
No digit up
For example, when it is started from address 0Eh,
therefore, increment is made as below,
0Eh→0Fh→00h→01h ---, which please note.
*0Eh --- 0E in hexadecimal, therefore, 00001110
4. Write protect terminal (WP)
becomes a binary number.
(1) Write protect function
When WP terminal is set Vcc (H level), data rewrite of all addresses is prohibited. When it is set GND (L level), data
rewrite of all addresses is enabled. Be sure to connect this terminal to Vcc or GND, or control it to H level or L level.
Do not use it open.
At extremely low voltage at power ON/OFF, by setting the WP terminal “H”, mistake write can be prevented.
During tWR, set the WP terminal always to “L”. If it is set “H”, write is forcibly terminated.
www.rohm.com
© 2012 ROHM Co., Ltd. All rights reserved.
TSZ22111・15・001
14/26
TSZ02201-0R2R0G100470-1-2
17.Sep.2013 Rev.002