BD9560MUV_09 Datasheet, PDF (11/22 Pages) Rohm – Switching Regulator Controller for Graphic Chip Cores
BD9560MUV
4. MOSFET Selection
VIN
main switch
L
Co
VOUT
synchronous switch
5. Setting Detection Resistance
VIN
L
R
IL
VOUT
Co
Technical Note
Loss on the main MOSFET
Pmain=PRON+PGATE+PTRAN
=
VOUT
VIN
×RON×IOUT2+Ciss×f×VDD+
VIN2×Crss×IOUT×f
IDRIVE
・・・(11)
(Ron: On-resistance of FET; Ciss: FET gate capacity;
f: Switching frequency Crss: FET inverse transfer function;
IDRIVE: Gate bottom current)
Loss on the synchronous MOSFET
Psyn=PRON+PGATE
= VIN-VOUT ×RON×IOUT2+Ciss×f×VDD ・・・(12)
VIN
The over current protection function detects the output ripple
current bottom value. This parameter (setting value) is
determined as in formula (13) below.
ILMIT= VCL×1/16 [A]・・・(13)
R
(VILIM: ILIM voltage; R: Detection resistance)
Current limit
VIN
IL
L RL
r
C
VOUT
Co
Current limit
6. Setting Load Line Slope
VIN
HG
IL
LG
SS
VDAC
LSP
R1
LSM
R1
Amplifier for setting
Load slope
FB R2
When it detect the over current protection from DCR of “the coil L”, this
parameter (setting value) is determined as in formula (14) below.
ILMIT=VCL×1/16× r×C
L
[A]・・・(14)
(RL=
L
r×C
)
(VCL:CL voltage RL:DCR value of the coil)
RSENSE
R2
FB =
×RSENSE×IL+ RSENSE×IL+VOUT
VOUT
R1
R2
= (1+ R1 ) × RSENSE×IL+VOUT
So that,
R2
SLOPELL = (1+ R1 ) × RSENSE
(SLOPELL : Load Line Slope)