BD9018KV Datasheet, PDF (1/17 Pages) Rohm – Step-down,High-efficiency Switching Regulators (Controller type) | |||
|
Large Current External FET Controller Type Switching Regulators
Step-down,High-efficiency
Switching Regulators (Controller type)
BD9018KV
No.10028EAT15
âOverview
The BD9018KV is a 2-ch synchronous controller with rectification switching for enhanced power management
efficiency. It supports a wide input range and leads to eco-design (low power consumption) for various electronics.
âFeatures
1) Wide input voltage range: 3.9Vï½30V
2) Precision voltage references: 0.8V±1%
3) FET direct drive
4) Rectification switching for increased efficiency
5) Variable frequency: 250kï½550kHz (external synchronization to 600kHz)
6) Built-in auto-recovery over-current protection
7) Separate enable-pins per CH for individual power up/down control
8) Supports various applications: step-down, step-up, and step-up-down
9) Small footprint packages: VQFP48C
10) When operating at Max Duty, the switching frequency slows down to 1/5 to reduce input/output difference.
âApplications
Car audio and navigation systems, CRTTVï¼LCDTVï¼PDPTVï¼STBï¼DVDï¼and PC systemsï¼portable CD and DVD
players, etc.
âAbsolute Maximum Ratings (Ta=25â)
Parameter
Symbol
Rating Unit
Parameter
Symbol
VCC Voltage
VCC
35 *1
V
PGOOD Voltage
PGOOD
EXTVCC Voltage
EXTVCC
35 *1
V
SS1,2 Voltage
SS1,2
VCCCL1,2 Voltage
VCCCL1,2
35 *1
V
FB1,2 Voltage
FB1,2
CL1,2 Voltage
CL1,2
35
V
COMP1,2 Voltage
COMP1,2
SW1,2 Voltage
SW1,2
35 *1
V
RT Voltage
RT
BOOT1,2 Voltage
BOOT1,2
40 *1
V
SYNC Voltage
SYNC
BOOT1,2-SW1,2
BOOT1,2-SW1,2
7 *1
V
Voltage
Power Dissipation
Pd
Operating
temperature
Topr
EN1,2 Voltage
EN1,2
EXTVCC
V
Storage temperature
Tstg
VREG5,5A
VREG5,5A
7
V
Junction
temperature
Tj
*1 Regardless of the listed rating, do not exceed Pd in any circumstances.
*2 Mounted on a 70mm x 70mm x 1.6mm glass-epoxy board. Reduce by 8.8mW/â (VQFP48C) above 25â.
Rating
Unit
7
V
VREG5
V
1.1 *2
W
-40ï½+85
â
-55ï½+150
â
+150
â
www.rohm.com
âc 2010 ROHM Co., Ltd. All rights reserved.
1/16
2010.02 - Rev.A
|
▷ |